Burner And Nozzle Specifications - Indesit IP 640 Mode D'emploi

Masquer les pouces Voir aussi pour IP 640:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Burner and nozzle specifications

GB
Table 1
Burner
Fast (R)
Reduced Fast
(RR)
Ultrarapid (UR)
Semi Fast (S)
Auxiliary (A)
Mini WOK (MW)
Supply
Pressures
*
At 15°C and 1013 mbar-dry gas
**
Propane
***
Butane
Natural
(1) Only for appliances with the security device.
S
S
IP 640
IP 640 S
IP 640 S R
RR
UR
A
IP 750 S
IP 750 S R
16
Diameter
Thermal power
(mm)
kW (p.c.s.*)
Nomin.
Ridot.
100
3,00
0,70
100
2,60
0,70
100
3,40
0,70
75
1,65
0.40
55
1,00
0,40
110
3,50
1,30
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
P.C.S. = 50.37 MJ/kg.
P.C.S. = 49.47 MJ/kg.
P.C.S. = 37.78 MJ/m
3
R
S
A
S
IP 641 S
IP 641 S GH
S
RR
S
A
IP 751 S
IP 751 S R
IP 751 S GH
Liquid Gas
By-Pass
Nozzle
1/100
1/100
(mm)
(1)
(mm)
41
39
86
41
39
80
41
39
91
30
28
64
30
28
50
-
57
91
MW
A
S
MW
S
Natural Gas
Flow*
Nozzle
g/h
1/100
***
**
(mm)
218
214
116
189
186
110
247
243
123
120
118
96
73
71
79
254
250
138
28-30
37
20
25
35
45
Flow*
l/h
286
248
324
157
95
333
20
17
25

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ip 640 sIp 641 sIp 640 s rIp 751 s rIp 750 sIp 751 s ... Afficher tout

Table des Matières