Checking The Seal; Rock Spare Parts - Dovre ROCK 350 Installation Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Checking the seal

Check whether the door sealing rope is still in good
condition and works well. The sealing rope is
subject to wear and will need to be replaced over
time.
Check the appliance for air leaks. Close any
chinks with stove sealant.
Allow the sealant to harden fully before lighting
the appliance, as any moisture in the sealant
will form bubbles, resulting in a new air leak.
Adjust door closing
Check if the door closes properly. If required, the clos-
ing of the door can be set looser or tighter by adjusting
the distance between the locking cam and the door.
Proceed as follows:
1. Open the door.
2. Remove the right baffle plate.
3. Loosen nut (1) on the inside of the appliance.
4. On the inside adjust the locking cam (2) using an
Allen key.
5. Tighten nut (1) again.
6. Close the door.
1
Replacing the glass
If the glass in the appliance is broken or
cracked, it must be replaced before the stove
is used again.
Proceed as follows:
Subject to change because of technical improvements
1. Unscrew the four glass fixings with parts (1) and
(2) and remove the glass (3), see following figure.
2. Check the glass seal and, if necessary, fit a new
sealing rope.
3. Place the new glass in the grove and tighten the
glass fixings.

ROCK spare parts

4
2
11
09-20021-161
1
3
2
8
10
1
3
2
09-20021-162
6
5
7
9
09-20021-153
19

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Rock 500Rock 350 tbRock 500 tbRock 350 wbRock 500 wb

Table des Matières