Installation
r
2 Cutout Dimensions and Clearances
Reference
Dimension
30.0 in. (762 mm) Minimum clearance*
q
2.4 in. (61 mm)
w
20.3 in. (516 mm) Cutout width
e
16.0 in. (406 mm) Cutout height
r
17.8 in. (452 mm)
t
1.8 in. (46 mm)
y
1.5 in. (38 mm)
u
* The minimum clearance to combustible materials allowed from the
surface of the range to a combustible object (curtains, board, wall,
floor, etc.). Consider both sides, the back side, and above the cabinet
when determining clearances. CSA certification requires a minimum top
clearance of 30.0 in. (762 mm) to overhead combustible construction
when installed with a range hood spaced a minimum of 0.25 in. (6 mm)
from the construction.
I
The maximum depth of cabinets installed above the
range is 13 in. (330 mm).
6
y
q
u
t
w
e
Description
Minimum distance from the
range to a wall or cabinet
Cutout depth
Distance between the
counter and the power
cord outlet
Distance from the power
cord outlet to the counter
e
3 Range Dimensions and Clearance to Walls
Reference
Dimension
9.0 in. (229 mm)
q
8.0 in.(203 mm)
w
21.3 in. (541 mm)
e
17.8 in. (452 mm)
r
7 Installation
WARNING: FIRE, EXPLOSION, BURN, AND/
OR CARBON MONOXIDE HAZARD. Failure to
obey the following warnings could result in
death or serious injury.
• Gas leaks may occur in your system and may not be
detected by smell alone. Gas suppliers recommend
you purchase and install a UL-approved gas detector
and alarm. Install and use in accordance with the
manufacturer's instructions.
• Do not use matches, candles, or other sources of
ignition to test fittings and gas lines for leaks.
• Do not install any structure directly above the stove
(for the width of the stove) except a range hood.
CRG 3000 Series Range
q
w
r
Description
Minimum clearance to rear
wall from burner center
Minimum clearance to side
wall from burner center
Range width
Range depth