A DIN Rail mounting plate is available as an accessory (CX-DR2).
This allows mounting the controller on a standard 35mm DIN rail.
Remove the screws at the backside of the controller and screw
the mounting plate with the (long) fastening screw onto the
backside of the controller.
2
WARNING: If the battery is connected with reverse polarity,
the load terminals will also have the wrong polarity. Never
connect loads during this condition!
Connect the wires leading to the battery
with correct polarity. To avoid any
voltage on the wires, first connect the
controller, then the battery. Mind the
recommended wire length (min 30 cm
to max approx. 100 cm) and the wire
size:
CML05: min 2.5 mm
CML08: min 4 mm
CML10: min 6 mm
CML15, CML20: min 10 mm
Wrong polarity will cause a permanent
warning sound.