Name plate not illuminated
Power supply is missing
Polarity of power supply is reversed
Check connection from name plate to basic electronics
Door opener is not triggered
Check door opener connection
Power supply for door opener missing
on-site (do not connect in parallel to Behnke power supply)
Telephone does not send DTMF tones -> cf.: Door intercom device cannot be configured
Code for opening doors is not or wrongly configured (default setting 0#)
Confirm code entry with #
Door intercom device without function
Check a / b port, measure if necessary
If additional power supply is connected, check if it is potential-free
Multiple door intercom devices are connected in parallel
logue connection and its own potential-free power supply
Coil current of the telephone system is sufficient
must be more than 20mA
Cf: Technical Specifications of the door intercom device
Occasional call activation of door intercom devices
Additional call buttons connected, remove buttons, do not connect buttons in parallel
Please note the button connection cable length if the basic electronics is detached. Please refer
to the corresponding basic electronic details.
External button connected, check button for functionality, bounce, freedom from potentials, no
common mass.
Delete configuration value (e.g. telephone number)
Start set-up mode
Enter configuration step and confirm with #
42
Use correct closing contacts
The set configuration value will be deleted.
each telephone requires its own ana-