Code Parameter
Operations modes Relay 1: Default: 00
08
00 = Relay is switched when entering the code (Configuration step 10)
for the activation time (Configuration step 09)
01 = Relay 1 is switched while button 1 is pressed
02 = Relay 1 is switched while button 2 is pressed
03 = Relay 1 is switched while button 1 and button 2 are pressed
04 = Relay 1 is switched while button 3 is pressed
05 = Relay 1 is switched while button 1 and button 3 are pressed
06 = Relay 1 is switched while button 2 and button 3 are pressed
07 = Relay 1 is switched while button 1, button 2 and button 3 are pressed
08 = Relay 1 is switched while button 4 is pressed
09 = Relay 1 is switched while button 1 and button 4 are pressed
10 = Relay 1 is switched while button 2 and button 4 are pressed
11 = Relay 1 is switched while button 1, button 2 and button 4 are pressed
12 = Relay 1 is switched while button 3 and button 4 are pressed
13 = Relay 1 is switched while button 1, button 3 and button 4 are pressed
14 = Relay 1 is switched while button 2, button 3 and button 4 are
pressed
15 = Relay 1 is switched while button 1, button 2, button 3
and button 4 are pressed
Relay 1 activation time: Default: 5
09
01 = 1 second
02 = 2 seconds
90 = 90 seconds
Relay 1 activation time: Default: 0
10
1. Activation code
The activation code consists of digits only and may be up to 4 digits long.
The relay is activated through voice connection via
DTMF with code #