Combustible Gas Leak Detector/English
3-Specific Safety Information
Warning
This section contains important safety information that is specific to this tool.
Read these precautions carefully before using the
Leak Detector to reduce the risk of fire, explosion or other serious personal
injury.
SAVE THESE INSTRUCTIONS!
Keep this manual with the tool for use by the operator.
3-1.Combustible Gas Detector Safety
1-High concentrations of combustible gases can cause explosions, fires, asphyxia and
other hazards that could cause serious personal injury or death. Know the characteristics
of the gas you are working with and use proper precautions to avoid hazardous
conditions.
2-Always turn on and calibrate the gas detector in an area known to be free of
combustible gases. Calibration in an area containing combustible gas will result
in incorrect calibration and lower than actual readings. This could result in
combustible gases not being detected.
4-Description, Specifications And Standard Equipment
4-1.Description
The MICRO
combustible gas leak Detector
identify the presence of and isolate the source location of combustible gases such as
methane, propane, butane, ammonia, carbon monoxide and many others(please see
back of manual for a more complete list). Even low levels of combustible gas can be
detected in seconds.
The MICRO Combusitble Gas Leak Detector detects gas concentrations through the use of
an internal sensor. This sensor is heated during operation. As the heated sensor interacts
with gases, the unit immediately indicates to the user that combustible gases are present.
4
Combusitble Gas
MICRO
is a gas leak locating tool that is used to
13/08/2017 Version No. 001
The Combusitble Gas Leak Detector indicates the presence of combustible gases with
visual, audio and vibration feedback mechanisms. It can detect different combustible gas
concentration 1-1000ppm or 0-10000ppm by setting high and low concentration detection.
When the tool senses the presence of a combustible gas, it will tell the operator
LCD display, triggering the appropriate audible alert or providing the appropriate
vibration alert.
The MICRO Combusitble Gas Leak Detector comes equipped with an attached flexible
16"probe hose.
4-2.Specifications
Visual Alert
LCD liquid crystal display of flammable gas concentration
of reading, Article Simulation Indications(fast and accurate).
Audible Alert(85db)
Loud Audible Ticking Rate(The sound frequency is directly
proportional to the concentration of gas)
Vibration Alert
Standard
Sensitivity
<10ppm(methane)
Response Time
<2 Seconds
Range
Low concentration range 0-1000ppm(methane)High
concentration range 0-10000ppm(methane)
Warm Up Calibration
Automatic
Warm Up Time
40 Seconds
Operating Buttons
Seven: Power ON/OFF, High/Low Sensitivity Audio Alerts,
Vibration Alerts, Auto Zero,Auto Power Off, Back Light
Batteries
Polymer Li-Ion Battery
Automatic shutdown
Low power automatic shutdown and automatic shutdown
for 10 minutes without operation.
Sensor replacement
Can replace
Expected Sensor Life
5 Years
Probe
Flexible 16"/400mm
13/08/2017 Version No. 001