Combustible Gas Leak Detector/English
9-Restore factory settings
After warming up for 40s the MICRO Combusitble Gas Leak Detector will be under
measurement status. Then press both the High/Low Sensitivity button and the buzzer
button all the time and it will beep, which means it is under factory setting status. Keep
pressing both the High/Low Sensitivity button and the buzzer button and also press
vibration button 4 times and then the Autozero button 4 times, the equipment will
produce a beep successfully, Icon(RESET) will be diplayed on the LCD which means you
have entered to resume production setting mode. At this time all the buttons can be
released. After RESET icon dispear the user has finished factory setting.
10-Storage
The MICRO Combusitble Gas Leak Detector must be stored in a dry secure area between
-10°C(14°F)and 60°C(158°F).
Store the tool in a locked area out of the reach of children and people unfamiliar with the
MICRO Combusitble Gas Leak Detector.
Remove the batteries before any long period of storage or shipping to avoid battery
leakage.
11-Disposal
Parts of the MICRO Combusitble Gas Leak Detector contain valuable materials and can be
recycled. There are companies that specialize in recycling that may be found locally.
Dispose of the components in compliance with all applicable regulations. Contact your
local waste management authority for more information.
12-Troubleshooting
PROBLEM
POSSIBLE REASON
Pressing and releasing the
The battery is discharged
ON/OFF button for one
second. But meter does not
work.
All display are flashing and
The sensor(or the sensor
beeping at the same time.
heater) is defective.
The logo CAL will flash
The calibration is wrong
when exiting calibration
12
SOLUTION
The batteries are low and
need to be charged.
Shut OFF unit. Sensor or
entire unit should be
checked or replaced.
Check the meter and
environment, do calibration
again, if it still flashes, you
can contact the after-sales
13/08/2017 Version No. 001