WARNING
!
All wiring should be done by a qualifi ed electrician and shall be in compliance with local codes and with the National
Electrical Code ANSI/NFPA No. 70-Current (in the U.S.A.) or with the current CSA22.1 Canadian Electrical Code (in
Canada).
4. Electrical Connection
a)
NZ6000 ONLY:
Remove
the junction box covers on the unit and the blower. Note:
There are two covers on the unit. The front cover must
never be covered or concealed by fi nishing
material. (See Installation Instructions -
Framing) The front cover is accessed by
removing the front faceplate.
b) Removing the junction box cover on the unit
exposes 4 black, labeled wires:
-2 wires marked by-pass - go to by-pass (summer)
switch (not supplied) (overides the thermally activated switch).
IMPORTANT: Wire-nut by-pass switch (summer) wire leads
separately, if not being used.
-1 marked blower - connects to Fan Speed Control (rheostat) and
then to white blower wire.
BY-PASS (SUMMER)
SWITCH
NOT SUPPLIED
THERMAL DISC
Activates blower when
temperature is reached.
FAN-SPEED CONTROL
(RHEOSTAT {VARIABLE SPEED SWITCH})
or WALL SWITCH or THERMOSTAT
-1 marked L1 - connects to power (hot lead).
Removing the junction box cover on the blower exposes
3 coloured wires:
-1 black wire - goes to power L2 (neutral lead).
-1 green wire - connects to ground.
-1 white wire - connects to Fan Speed Control
(rheostat) which connects to "blower" wire.
SWITCHES IN A CONVENIENT
W A
M B
C O
E R
A V
C O
A IR
S E
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada •
MANDATORY:
INSTALL THE FAN SPEED
CONTROL AND BY-PASS
LOCATION
G :
IN
R N
E R
L Y
W A
O N
O W
B L
N
N T
:
T IO
E C
M E
L A
N N
S E
D E
C O
T IS
N
E R
IO
IE
E X
E R
G :
A V
F L
T
A IR
N N
U F
E N
IN
C O
E M
R N
N
S O
U L
T IO
U S
S E
L Y
:
O N
N T
M E
A N
T
S E
T IS
U R
M B
T
E N
E M
U L
Allow for
thickness of
finishing
material
5.
Connect the 6" liner to the unit and blower collars. Secure using
3 screws on each end and seal with caulking.
Liner supplied stretches to a maximum of 10'. If additional
DOOR PRESSURE SWITCH
Safety switch shuts off blower
when glass doors are opened.
L1
G
FAN
L2
NZ150-KT KIT
The 6" circulation
air inlet may
blower kit or the NZ150-KT kit.
The circulation inlet must terminate outside of the fi replace
enclosure to ensure proper air fl ow around the fi rebox.
Avoid terminating higher than the bottom of the doors on the unit to
prevent air fl ow reversal.
An optional opening is covered on the other side of the unit. If this
location is preferred, switch the cover plate and collar.
1(866)820-8686
FILTER
GRILL
lengths are required, secure
each joint in the same way.
6. Insert the fi lter into the
1
grill. Foam gasket (
/
" weather
2
stripping) between the grill and
blower housing is
recommended, but not
supplied. The blower
fi lter is washable.
7. The bottom lip of the grill
latches over the bottom lip of
the housing. Use two screws to
secure the top of the grill to the
facing.
(NZ6000 ONLY)
be
connected to either the NZ64
W415-0882 / C / 02.14.20
www.napoleon.com