CONFIGURATION
0
Default settings: default indoor station settings are:
Door unit number:
0
Type of station:
main
Secondary station address:
0
Door opener:
Private
Interruption:
Not enabled
Camera lights:
on
Number of users:
single-family
Guaranteed communication time rotary: 30 s (pos 3)
Door lock dip-switch:
Instantaneous (pos 0)
ID:
door unit number
Set a number from 0 to 3 if the door unit is a main unit (v. AUX dip 1) or from 0 to 31 if the door unit is a
secondary unit as shown in the following fi gure.
ID=0
ID=1
ID=2
ID=8
ID=9
ID=10
ID=16
ID=17
ID=18
ID=24
ID=25
ID=26
There must not be two main stations with the same ID. Two secondary stations may coexist with the
same ID but with different address (v. AUX dip 2).
The ID of the secondary door unit must coincide with the column ID set in the column interface 1083/50,
if present.
12
O N
O N
=
=
ID
ID=3
ID=4
ID=5
ID=6
ID=7
ID=11
ID=12
ID=13
ID=14
ID=15
ID=19
ID=20
ID=21
ID=22
ID=23
ID=27
ID=28
ID=29
ID=30
ID=31
AUX:
auxiliary settings
Station type: the door unit can be confi gured either as a main or a secondary device. All the users in the
system may be called from the main door unit. A secondary door unit may only call the users of the column
to which it belongs. Users can identify the source of the call by the ring tone.
Secondary station address: Two secondary calling stations may be present in a column and must have a
different address
Door opener: The electric lock can be managed in "privacy" or "free" mode. The door unit works as follows
in the two cases:
"Privacy": the electric lock may only be activated by pressing the door opening button on the calling
station when an audio conversation has been established or when after having received a call or auto-
on function either a video connection has been established.
"Free": when pressing the door lock release button of an apartment station, the door unit electric lock
can be activated only if the door unit is confi gured as main or the user belongs to the column of the
same secondary door unit. This column is defi ned by the ID setting of the secondary door unit. This
function is typically used for secondary stations.
Interruption: where is in progress an auto-on or an intercom conversation the respective column or the
whole system is in busy mode, which, according to the confi guration of this switch, can be interrupted or
not by a call from the door unit.
The parameter "interruption" must be programmed in the same way for all system call stations.
Camera lights: the camera lights may be turned off if illumination in the surrounding environment is suffi cient
at night.
Number of users: the tilting call key can call two different users (user 0 if pressed to the left and user 1 if
pressed to the right) or a single user if pressed on the right and left side.
Dip 1
Dip 2
Dip 3
Dip 4
Dip 5
Dip 6
DS1783-005
DS1783-005
AUX
Station
Main
type
Secondary
station
Secondary 0
address
Door opener
Door opener
free
Interruption
On
Camera
Camera
lights
lights
off
Number of
Single-family
users
Secondary
Secondary 1
Door opener
privacy
Off
Camera
lights
on
Two-family
13