Detailed Performance Data for Use on Round Pipes
Values shown for load capacity of the TML 400R are based on material S235 JR for the maximum, vertical tractive
force with 0° deviation from the load axis and a correct position of the pipe inside the groove of the magnetic
contact area. The safety factor corresponds to at least 3:1 in all cases.
Table 3: Round pipes
mm
inches
Rust, paint or any other surface coating may cause an air gap that will reduce the load-bearing capacity according
to the following table.
Table 4: Air gap on round pipes
Air gap in mm
Air gap in inch
Remaining load
capacity in %
Quick and abrupt rotations of the magnet can cause round object to disengage from the
magnet's groove. This will reduce the load-bearing capacity immediately.
Never lift round pipes laterally or exceed the load-bearing capacity given in table 3 & 4.
Load capacity in kg
50
75
>10
150
200
8
145
200
5
130
175
4
95
130
3
75
100
Load capacity in lbs
2"
3"
>3/8
330
440
5/16
319
440
0.20
286
385
0.16
209
286
1/8
165
220
0
0,2
0
0,0078
100
89
100
200
175
200
175
200
150
175
112
130
90
100
4"
8"
385
440
385
440
330
385
246
286
198
220
0,4
0,6
1,0
0,0157
0,0236
0,0393
75
65
45
400
-
-
-
-
16"
-
-
-
-
1,5
0,0590
30
25