Technical Data
Prod.-No.:
Designation:
Breakaway force:
Max. load-bearing capacity:
(on flat material
with safety factor 3:1)
Max. load-bearing capacity:
(at 6° inclination acc. to EN 13155
with safety factor 3:1)
Max. load-bearing capacity:
(at 90° inclination of the load
with safety factor 3:1)
Dead weight of the unit:
Admissible diameter of round
pipes:
Max. load-bearing capacity:
(on round pipes at 0° inclination)
Storage temperature:
Operating temperature:
Markings on the Lifting Magnet
Additional detailed descriptions for handling and operating conditions can be found on both sides of the lifting
magnet. This labeling must not be modified, damaged or removed, as otherwise the manufacturer cannot be held
responsible for any personal injuries, property damage or accidents resulting from this fact. New labels must be
ordered from the manufacturer if necessary.
41400.R
TML 400R Lifting Magnet
>1200 kg from 15 mm S235
400 kg from15 mm S235
340 kg from15 mm S235
120 kg from15 mm S235
8.2 kg
50 - 400 mm
20 - 50% of the load-bearing
capacity for flat material
-30°C to +60°C
-10°C to +60°C
(Prod.-No.189414177.R)
(Prod.-No.189414178.R)
>2640 lbs from ½" AISI CRS 1020
880 lbs from ½" AISI CRS 1020
750 lbs from ½" AISI CRS 1020
264 lbs from ½" AISI CRS 1020
18 lbs
2"- 16"
20 - 50% of the load-bearing
capacity for flat material
-22°F to +140°F
+14°F to +140°F
17