As soon as the Calciumreactor is placed in the right position and all connections are ready, the
water flow can be started. Then, the reactor is filled up with water until water comes out of the
outlet. Afterwards, the CO
can be switched on. The quantity of CO
has to be adjusted the way
2
2
that the pH-value in the aquarium does not drop below pH 7.8. Within the reactor itself, the pH-
value should drop to pH 5.9 - 6.0. It is possible to control the pH-value in the reactor by e. g. the
Aqua Medic pH-Controller or the pH Computer. In the top, there is a hole to srew in a pH
electrode.
The back flow of the calciumbicarbonate enriched water either into the aquarium or filter tank
should be directed to a well-flushed place in order to mix it immediately with aquarium water. This
avoids instabilities of the pH-value.
6. Maintenance
The Aqua Medic Hydrocarbonate is consumed by the chemical reaction and has to be refilled from
time to time. Every 1 - 2 years, it should be replaced completely. Also the flow rate should be
checked regularly.
7. Warranty
Should any defect in materials or workmanship be found within 24 months of the date of purchase
AB Aqua Medic undertakes to repair, or at our option replace, the defective part free of charge –
always provided the product has been installed correctly, is used for the purpose that was intended
by us, is used in accordance with the operating instructions and is returned to us carriage paid.
Proof of Purchase is required by presentation of the original invoice or receipt indicating the
dealer's name, the model number and date of purchase. This warranty may not apply if any model
or production number has been altered, deleted or removed, unauthorised persons or organisations
have executed repairs, modifications or alterations, or damage is caused by accident, misuse or
neglect. Please note that the product is not defective under the terms of this Warranty where the
product, or any of its component parts, was not originally designed and / or manufactured for the
market in which it is used. These statements do not affect your statutory rights as a customer.
AB Aqua Medic GmbH - Gewerbepark 24 - 49143 Bissendorf/Germany
- Technical changes reserved – 03/2017
Current manuals are available for download at www.aqua-medic.de.