The LED display shows the set temperature of the cooling function� The
room temperature is shown at the dehumidifying and fanning functions� The
LED display also shows the following error and safety codes�
Error codes
• E2 Temperature sensor error
• E3 Condenser temperature sensor error
• E4 Water reservoir is full
Water reservoir is full
Connect the drain hose to the bottom water drainage point and let the
collected water run off (also see the section on water drainage)� If this safety
code recurs, contact your supplier�
! !
REMARK
• When one of the aforementioned faults occurs, switch off the
airco and check for possible obstacles� Restart the airco� If the
fault persists, switch off the airco and take the plug out of the
socket� Contact your supplier�