THERMOBILE AT 306 Manuel De L'utilisateur page 12

Masquer les pouces Voir aussi pour AT 306:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
Description
Clean the oil overflow pipe in the floor of the combus-
tion chamber, see fig. 4 (G) for AT 306 and see fig. 6
(G) for AT 307.
Clean the oil supply pipe.
Replace the oil supply pipe when this is burnt out or
damaged.
Check the oil pipes for leakage.
Clean the fuel tank, the supply filter and the fuel filter.
The fuel tank can easily be removed.
Only for the AT 307: Check the hot air fan and clean if
necessary.
Clean the flue stack valve in the T-piece, see fig. 9 (A).
The recommended draught is 1.5 mmwk (0.06" water
column).
Clean the flue stack T-piece, see "cleaning the flue
stack valve".
Check the heater's wiring.
Hot
Do not touch the flue stack or
combustion chamber!
Do not perform maintenance until the
flue and combustion chamber have
cooled down.
5.2
General
Warning
Switch off the power supply before
carrying out any repairs!
When the heater is stored long-term:
1. Switch off the heater.
2. Disconnect the power plug.
12
3. Clean the heater.
4. Use an oily cloth to clean the combustion
chamber, to protect the combustion
chamber against corrosion.
5.3
1. Remove the afterburner (A), the cylinder
(C) and the upper ring (D).
2. Clean the parts with a steel brush.
3. Remove the burner dish (E) with the hook
of the shovel (F).
4. Scrape off residues from the burner dish
with a scraper.
40.020.941 - rev. 04 - 2011
Period
Every
Weekly Monthl
12
y
hours
X
X
X
X
X
Dealer
Warning
Do not operate the heater in hot
weather to burn oil.
Cleaning the combustion chamber
AT 306(fig. 10)
Annu-
ally
X
X
AT 300-US series

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

At 307 us

Table des Matières