9. Check the floor surface: this needs to be
2
at least 388 ft
.
10. Install the flue (18 ft and a rain cap).
11. Make sure the rocker switch is positioned
at 0.
12. Check the supply voltage: see
identification plate.
13. Place the plug in the socket.
3.3
Preparation for starting up AT 306
1. Switch control of the fuel pump to "low",
see fig. 5 (D).
2. Remove the grate, see fig. 3 (A), the
cover of the combustion chamber,
cylinder afterburner and the upper ring,
see fig. 4 (A, C and D).
3. Check whether the burner dish is clean
and cold.
4. Clean the burner dish and the floor of the
combustion chamber if necessary.
5. Pour 0.2 litre of diesel oil onto the burner
dish, see fig. 4 (F).
Warning
Never pour diesel oil onto a hot
burner dish.
The burner dish must be cool!
6. Re-position the upper ring, the
afterburner and the cylinder.
7. Form a paper pellet and light it.
8. Drop the burning pellet on the burner
dish.
9. Reposition the cover of the combustion
chamber and the grate.
3.4
Preparation for starting up AT 307
1. Switch the control of the fuel pump to
"low", see fig. 5 (D).
2. Push the tank bolt up, see fig. 3 (P).
3. Open the cover of the of the combustion
chamber (fig. 6 A) and open the cover of
the heat shield ( fig. 6 (C).
4. Check whether the burner dish is clean
and cold.
5. Clean the burner dish and the floor of the
combustion chamber if necessary.
10
6. Pour 0.2 litre of used oil onto the burner
dish, see fig. 6 (F).
7. Form a paper pellet and light it.
8. Drop the burning pellet on the burner
dish.
9. Close the heat shield.
10. Close the heat distributor.
3.5
Automatic operation:
1. Switch the rocker switch to "2", see fig. 5
(A).
The combustion air fan starts running
(only with AT 307).
When the burner dish has reached the
right temperature, the fuel pump starts
running and the control light is on.
40.020.941 - rev. 04 - 2011
Warning
Never pour diesel oil onto a hot
burner dish.
The burner dish must be cool!
Starting up
Warning
Never pour diesel oil onto a hot
burner dish. The burner dish
must be cool and clean!
Do not start the heater if the fan
still runs. The heater is cooling
down.
Do not start the heater if excess
oil has accumulated in or near
the heater.
Caution
Do not switch on the convector
heater if there is no fuel, or if the
connected fuel tank is empty.
Caution
Only the following oil types may be
used in the stationary used oil fired
heaters:
Automatic transmission oil
Crankcase oil
Diesel oil
Hydraulic oil
Domestic fuel oil
AT 300-US series