• We recommend that you always change just one
setting value and see what effect this has.
• CV 8 is an important CV. Writing the value „8" will
result in the complete component being reset to the
factory settings that applied at the time of delivery!
Designation
Locomotive address
Starting voltage
Acceleration time
Braking time
Top speed
Middle speed
Basic setting
Expanded locomotive
address
16
DCC Address of the locomotive
Changes the minimum speed
Value * 0,87 gives the time from shutdown to top speed
Value * 0,87 gives the time fromtopspeed to shutdown
Speed of the locomotive at the top level
Speed of the locomotive at the middle speed level. CV 6 must be
Restore basic factory settings
Long address: CV 17 = higher-value bit.
Long Address must be activated in CV 29/bit 5
Meaning
less than CV 5
Factory
Area
CV
setting
1
1 - 127
3
0 - 64
2
4
3
0 - 64
8
4
0 - 64
6
5
0 - 64
63
6
0 - 64
25
-
8
8
128
17/18
0
- 9999