Operating instructions
Electronic position indicator
and electronic frequency meter
C C O O D D I I X X 5 5 4 4 P P
1.1 Safety instructions and warnings
Only use this display
– in a way according to its intended
purpose
!
– if its technical condition is perfect
– adhering to the operating
instructions and the general
safety instructions.
1.2 General safety instructions
1. Before carrying out any installation or maintenance
work, make sure that the power supply of the digital
display is switched off.
2. Only use this digital display in a way according to
its intended purpose:
If its technical condition is perfect.
Adhering to the operating instructions and the
general safety instructions.
3. Adhere to country or user specific regulations.
4. The digital display is not intended for use in areas
with risks of explosion and in the branches exclud-
ed by the standard EN 61010 Part 1.
5. The digital display should only operate if it has been
correctly mounted in a panel, in accordance with
the chapter "Main technical features".
1.3 Use according to the intended
purpose
The digital display may be used only as a panel-
mounted device. Applications of this product may
be found in industrial processes and controls, in
manufacturing lines for the metal, wood, plastics,
paper, glass, textile and other processing indus-
tries.
Over-voltages at the terminals of the digital dis-
play must be kept within the limits in Category II
If the digital display is used to monitor machines
or processes in which, in case of a failure of the
device or an error made by the operator, there
might be risks of damaging the machine or caus-
ing accidents to the operators, it is your responsi-
bility to take appropriate safety measures.
1.4 Description
• 6-digit position indicator and frequency meter
• Red LED display, character height 14 mm
• Display range -199 999 ... 999 999
• Leading zeros suppression
• Programming via two setting keys on the front
side
• During programming, the display guides the
user with text prompts
• Position indicator operating modes
– Count input INP A + count direction input
INP B(Cnt.Dir)
– Differential count INP A - INP B (up.dn)
– Totalising INP A + INP B (up.up)
– Count Up/Down INP A 90° INP B x 1
(quad)
– Count Up/Down INP A 90° INP B x 2
(quad2)
– Count Up/Down INP A 90° INP B x 4
(quad4)
• Frequency meter
– Frequency input INP C
– Value conversion and display in 1/s or
1/min
• With AC power supply: sensor supply
voltage 24 V DC ±15 %/100 mA.
2. Inputs
INP A
Dynamic count input.
INP B
Dynamic count input.
INP C
Dynamic frequency input.
7