Count frequency:
AC power supply: 90 ... 260 V AC
Input level:
Standard
typ. level low:
typ. level high:
22,0 V
Fmax:
kHz
ContDir/Tacho
20
UpDown/Tacho
15
Up.Up/Tacho
15
Quad 1/Tacho
15
Quad 2/Tacho
15
Quad 4/Tacho
10
DC power supply:
24 12 V DC 10 ... 30 V DC
Input level:
Standard
typ. level low:
2,5 2,0 V
typ. level high:
22,0
Fmax:
kHz kHz
ContDir/Tacho
30
UpDown/Tacho
10
Up.Up/Tacho
10
Quad 1/Tacho
15
Quad 2/Tacho
15
Quad 4/Tacho
10
Frequency measurement (INP C):
Accuracy :
< 0.1 %
Measuring principle:
< 38 Hz:
period measurement
> 38 Hz:
gating time measurement
gating time = 26,3 ms
Input sensitivity:
Standard sensitivity:
AC power supply
Low: 0 ... 4 V DC
High: 12 ... 30 V DC
DC power supply
Low: 0 ... 0,2 x U
High: 0,6 x U
5 V sensitivity:
Low: 0 ... 2 V DC
High: 4 ...30 V DC
Pulse shape:
any,
Schmitt-Trigger inputs
Sensor supply voltage:
AC power supply
24 V DC ±15 %/100 mA
Ambient temperature:
–20 ...+65 °C
Storage temperature:
–25 ... +70 °C
5V
2,5 V
1,0 V
4,0 V
kHz
20
15
15
15
15
10
5V
1,0 V
10 V
4,0 V
kHz
10
8
10
8
10
8
10
8
10
8
10
8
[V DC]
B
... 30 [V DC]
B
EMC:
In compliance with the EC Directive 89/36/EEC
Noise emission
EN 61 000-6-3/
EN 55 011 Class B
Noise immunity
EN 61 000-6-2
Housing:
For front panel mounting: 96 x 48 mm
acc. to DIN 43700, RAL7021, dark gre
Weight:
appr. 150 g
Protection:
IP 65 (front)
Cleaning:
The front of the units is to be cleaned only with
a soft wet (water !) cloth.
7. Terminal assignment
X1
X1 Terminal assignment
Pin
AC Version
1
n.c.
2
n.c.
3
INP C
4
INP B
5
INP A
6
GND
7
+24 Vout
X2 Terminal assignment
Pin
AC Version
1
90 ... 260 V AC
2
90 ... 260 V AC
X2
DC Version
n.c.
n.c.
DC Version
0 V DC (GND)
10 ... 30 V DC
11