Time delay setting The values indicated in
Parameter displayed
t 0
Closing time (free passage)
t 1
Zone lighted time after end of cycle
t 2
Waiting time after passage in front of cell
t 3
Motor 1 and 2 ramp rate time
Operational control
and troubleshooting
Display
C 1
Control stand-by
C 2
Gate opening
C 3
Closing stand-by
C 4
Gate closing
C 5
DMAOP safety device blanked
C 6
Cell opening safety device blanked
C 7
Cell closing safety device blanked
C 8
Forced movement via keyboard
C 9
Emergency stop triggered
Safety device autotest in progress
C A
C b
Permanent control validated
C C
Time delay stand-by shutdown
before reversion
C d
Operation in battery mode
Complete list of parameters (cont.)
grey
Delay setting
Meaning
Display
25
correspond to factory settings.
Value displayed
00 to 99 s (05)
00 to 10 min (00)
00 to 99 s (00)
00 to 02 s (02)
E 1
Opening safety device default (always contact)
E 2
Closing 1 safety device default (always contact)
E 3
Closing 2 safety device default (always contact)
E 4
Opening safety device default (default autotest)
E 5
Closing 1 safety device default (default autotest)
E 6
Closing 2 safety device default (default autotest)
E 7
Overload 24V, intensity overrun
E 8
Intrusion default
E 9
Motor thermal safety device
E A
Motor slipping default
E b
Limit switch default
GB
Function
(1 s increment)
(1 min increment)
(1 s increment)
Meaning