8
2.4

rating plate information

For rating plate location, see "INSTALLATION OVERVIEW" section.
EN
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
B
DIRECT VENT GAS FIREPLACE APPROVED FOR BEDROOM, BATHROOM & BEDSITTING ROOM
INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE
CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED
STATES THE MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART 3280.
WHEN THIS US STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR
MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A. FOR USE ONLY WITH
BARRIER W565-0195. FOLLOW THE INSTALLATION INSTRUCTIONS LOCATED IN THE INSTALLATION MANUAL.
MANIFOLD PRESSURE: 3.5 INCHES W.C. (NG)
PRESSION AU COLLECTEUR: 3.5" D'UNE
MIN SUPPLY PRESSURE: 4.5" W.C.(NG)
PRESSION D'ALIMENTATION MIN: 4.5" D'UNE
MAX. SUPPLY PRESSURE: 7" W.C. (NG)
PRESSION D'ALIMENTATION MAX: 7" D'UNE
*ALTITUDE DOWNRATING CONDITIONS APPLY
TO CANADA ONLY /
NOT FOR USE WITH SOLID FUEL
FOR USE WITH GLASS DOORS CERTIFIED WITH THIS UNIT ONLY.
WARNING: DO NOT ADD ANY MATERIAL TO THE APPLIANCE,
WHICH WILL COME IN CONTACT WITH THE FLAMES, OTHER THAN
THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE.
DECORATIVE PRODUCT: NOT FOR USE AS A HEATING APPLIANCE
B-VENT MODELS GS28/CS280
APPROVED FOR BEDROOM, & BEDSITTING ROOM INSTALLATION.
THIS APPLIANCE MUST BE VENTED USING THE APPROPIATE
NAPOLEON VENT KIT. SEE OWNERS INSTALLATION MANUAL FOR
VENTING SPECIFICS. PROPER REINSTALLATION AND RESEALING IS
NECESSARY AFTER SERVICING THE VENT-AIR INTAKE SYSTEM.
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
MATERIAL: CLASS III A-2, PERMANENT LABEL, .010 VELVET MATTE LEXAN AND/OR .050 HI-TEMP POLYESTER, WATERPROOF,
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the
NON-WATER SOLUBLE ADHESIVE, CAPABLE OF WITHSTANDING A MAXIMUM TEMPERATURE OF 175° F (79° C).
appliance and must be installed.
MIN LETTERING FOR "NOT FOR USE WITH SOLID FUEL", "UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CELUI" TO BE
10 POINT ARIAL, BOLD FACE, UPPER CASE OR EQUIVALENT AND 2 POINT LEADING SPACING
BLACK LETTERING ON WHITE BACKGROUND
MAX OVERALL DECAL SIZE: 8.5" x 4.75"
SERIAL NUMBERS TO BE ASCENDING FROM GDS28
WOLF STEEL LTD.
TITLE: RATING PLATE LABEL GDS28 / CDVS280
REVISION: B: UPDATED CSA DATE & DESCRIPTION || 08.16.17_C.L.
W415-1426 / C / 07.31.18
CONFORMS TO / CONFORME AUX: ANSI Z21.50-2016, CERTIFIED TO / CERTIFIÉ CSA 2.22-2016 VENTED DECORATIVE GAS APPLIANCE / FOYER À GAZ VENTILÉ.
9700539 (WSL)
4001658 (NAC)
COLONNE D'EAU(GN)
NATURAL GAS MODEL
GDS28-N
CDVS280-N
COLONNE D'EAU (GN)
GS28-N
CS280-N
COLONNE D'EAU (GN)
0-4500FT
(0-1370m)
30,000 BTU/h
18,000 BTU/h
25,500 BTU/h
24,600 BTU/h
57.4%
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL /
DÉGAGEMENTS MINIMAUX DES MATÉRIAUX COMBUSTIBLES:
A
7"
D
B
2"
E
C
1"
F
20" TO CEILING FROM STOVE TOP
20" ENTRE LE DESSUS DU FOYER ET LE PLAFOND
ELECTRICAL RATING / CLASS.: 115V 1.5AMP 60HZ
MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHS ARE 25 INCHES AND 20 FEET RESPECTIVELY.
LES LONGUEURS HORIZONTALES MINIMALE ET MAXIMALE SONT 25 POUCES ET 20 PIEDS RESPECTIVEMENT.
THIS APPLIANCE MUST BE INSTALLED USING AN ADAPTER KIT GS-150KT. CET APPAREIL DOIT
ÊTRE INSTALLÉ EN UTILISANT UN ENSEMBLE ADAPTATEUR GS-150KT.
035149
FOYER À GAZ VENTILÉS À ÉVACUATION DIRECTE. HOMOLOGUÉ POUR INSTALLATION DANS UNE CHAMBRE À COUCHER,
UNE SALLE DE BAIN ET UN STUDIO. APPROPRIÉ POUR INSTALLATION DANS UNE MAISON MOBILE SI SON INSTALLATION
CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SÉRIE DE MAISONS MOBILES EQUIPÉES AU GAZ, EN
VIGUEUR AU CANADA OU AUX ÉTATS-UNIS DE LA NORME DE SÉCURITÉ ET DE CONSTRUCTION DE MAISONS
MANUFACTURÉES, TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ÉTATS-UNIS NE PEUT PAS ÊTRE
APPLIQUÉE, SE RÉFÉRER À LA NORME RELATIVE AU CRITÈRE DE MESURES DE SÉCURITÉ CONTRE L'INCENDIE POUR
LES INSTALLATIONS DANS LES MAISONS MANUFACTURÉS, LES SITES ET LES COMMUNAUTÉS, ANSI/NFPA 501A. POUR
UNE UTILISATION SEULEMENT AVEC BARRIÈRE W565-0195. SUIVEZ LES INSTRUCTIONS D'INSTALLATION DANS LE
4001657 (NGZ)
4001659 (WUSA)
PROPANE MODEL
GDS28-P
DIRECT VENT MODEL
GS28-P
'B' VENT MODEL
0-4500FT
ALTITUDE / ÉLÉVATION
(0-1370m)
*INPUT / ALIMENTATION*
26,000 BTU/h
REDUCED INPUT / ALIMENTATION REDUITE
15,000 BTU/h
OUTPUT(MODEL GDS28) RENDEMENT
22,360 BTU/h
OUTPUT(MODEL GS28) RENDEMENT
21,600 BTU/h
P4 (NG/LP) / (GN/PL):
57.4%
17½"
6¼"
9½"
SERIAL NUMBER / NO. DESERIE
MANUEL D'INSTALLATION.
MANIFOLD PRESSURE: 10 INCHES W.C.(LP)
PRESSION AU COLLECTEUR: 10" D'UNE
COLONNE D'EAU (P)
MIN SUPPLY PRESSURE: 11" W.C. (LP)
CDVS280-P
PRESSION D'ALIMENTATION MIN: 11" D'UNE
COLONNE D'EAU (P)
CS280-P
MAX. SUPPLY PRESSURE: 13" W.C. (LP)
PRESSION D'ALIMENTATION MAX: 13" D'UNE
COLONNE D'EAU (P)
*LES CONDITIONS DE BAISSE D'ÉVALUATION SELON L'ALTITUDE
S'APPLIQUENT AU CANADA SEULEMENT
UN COMBUSTIBLE SOLIDE NE DOIT PAS ÊTRE
UTILISÉ AVEC CET APPAREIL
UTILISER AVEC LES PORTES VITRÉES HOMOLOGUÉES SEULEMENT AVEC
CETTE APPAREIL.
AVERTISSEMENT: N'AJOUTEZ PAS À CET APPAREIL AUCUN MATÉRIAU
DEVANT ENTRER EN CONTACT AVEC LES FLAMMES AUTRE QUE CELUI QUI
EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT.
PRODUIT DÉCORATIF: NE PAS UTILISER COMME APPAREIL DE CHAUFFAGE
B-VENT MODELS GS28/CS280
HOMOLOGUÉ POUR INSTALLATION DANS UNE CHAMBRE À COUCHER ET UN STUDIO.
L'APPAREIL DOIT ÉVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'ÉVACUATION PROPRE
À NAPOLÉON. RÉFÉRER AU MANUEL D'INSTALLATION DE PROPRIÉTAIRE POUR
L'ÉVACUATION PRÉCISE. IL EST IMPORTANT DE BEIN RÉINSTALLER ET RESCELLER
L'EVENT APRÈS AVOIR ASSURÉ LE MAINTIEN DU SYSTÈME DE PRISE D'AIR.
GDS28
W385-1998 / B
PAGE 1 OF 2
DWG#: W385-1998
DATE: 12.11.14