6 - FURTHER DETAILS - ADVANCED MENU
The ADVANCED MENU allows the system to be further customised
by modifying parameters not accessible from the basic menu
To access the ADVANCED menu, press the MENU key and hold it
PARAMETERS
Electric brake
EL.F.
1
0 = off
1 = on
Use of PHOTO1 when starting from closed
SP.h.
0 = PHOTO1 is checked
2
1 = The gate starts even with PHOTO1 excited
Use of PHOTO2
Ph.2.
0 = Enabled during both opening and closing AP/CH
3
1 =Only enabled during opening AP
Photo-device test
0 = off
tP.h.
1 = PHOTO1 on
4
2 = PHOTO2 on
3 = PHOTO1 and PHOTO2 on
Sensitive edge type
Ed.m.
5
0 = contact (NC)
1 = resistive (8k2)
Sensitive edge tripping mode
0= only tripped during closure with direction reversal
iE.D.
6
1 = stops the automation (during both opening and
closure) and retreats from the obstacle
Edge test
tE.D.
7
0 = off
1 = on
LP.o.
8
Pedestrian opening
Time for automatic closure from pedestrian opening
TP.C.
9
(0=off)
Flashing light output setup
FP.r.
10
0 = Steady
1 = Flashing
tP.r.
11
Pre-flashing time (0 = off)
Courtesy light setup
0 = On at end of operation for time TCY
1 = On if gate not closed + duration of TCY
FC.Y.
12
2 = On if courtesy light timer (TCY) time not out
3 = Gate open light on/off
4 = Gate open light proportional flashing
tC.Y.
Courtesy light on time
13
Hold-to-run
de.a.
14
0 = off
1 = on
Service interval cycle threshold. Once the set
threshold is reached, the light flashes
se.r.
at high speed in all subsequent cycles (only if FPR is
15
on).
(0 = off)
Enabling of continuous flashing indicating
service required (only active with gate closed).
se.f.
16
0 = off
1 = on
de.f.
17
Restoring the default values
To set the default values: 1) access the advanced programming
function; 2) select the "dEf" parameter"; 3) activate the modification
mode ("0" on display"); 4) accept the modification (press "MENU"
down for 5 seconds
To modify ADVANCED MENU parameters, proceed as described
for the BASIC MENU
DESCRIPTION
and hold it down). A countdown should now appear: d80,d79...,d01
down to "
DEFAULT
MIN
CONFIGURATION
0
1
0
0
0
0
0
30
20
1
0
0
0
0
0
0
don
". Release the key when finished.
EN
MAX
UNIT
x 0.01s
0
100
(step of 5)
0
1
0
1
0
3
0
1
0
1
0
1
0
100
% (step of 1)
0
900
s
0
1
0
10
s
0
4
s
0
900
(step of 10s)
0
1
x 1000
0
100
cycles
0
1
23