f Secure the end strip to the roof battens with three of the
clamps provided. The clamps grip over the end strip and are
each secured using two of the nails provided on site.
Fitting position, right
1
1 Collector array end strip
2 Sealing strip
1
1 Drilled hole for the outlet Ø 27 mm
2 Drilled hole Ø 4.5 mm for securing to batten (distance 2080
mm from the inside edge of the mounting bracket)
3 Roof outlet
f Before the collectors are fitted, drill holes for the outlets in
the right and left collectors of the collector array at the posi-
tions provided (Ø 27).
Centring points are provided on the upper panel, indicating where
the hole for the outlet has to be drilled in the right-hand collector
and the position for the left-hand collector on the left-hand mark-
ing for the outlet. The flow line can be fitted on the right or left,
with the return line being fitted accordingly on the opposite side.
Note
Ensure that there are no rafters or battens causing ob-
structions near the roof outlet. If required, only drill the
hole once the collectors have been installed and move
the position of the hole.
qqq Z`.
<é<`VHC HB
2
D
3
2
1
f Position the collectors. Observe chapter "Lifting on to the
roof". Start with the right-hand collector.
Fitting position, right
1
1 Right-hand end strip
2 Sealing strip
f Hook the right-hand collector on to the collector array end
strip.
Fitting position, centre
f Hook the collectors together when fitting.
Fitting position, left
2
1 Right-hand end strip
2 Sealing strip
f Hook the left-hand collector array end strip on to the left-
hand collector.
f Secure the left-hand collector array end strip in the same
way as the right-hand one, using the clamps on the roof
battens.