Mounting and securing
6.4
Connect free-swing door closer electrical
Connect customer-supplied connection cable for free-swing door closer 24 V (J-Y (ST) Y2x0,8) to terminal 3 and 4.
X
With connector box (A)
Lay customer supplied connection cable for free-swing door closer 24 V (J-Y (ST) Y2x0,8) to connector box (A) and
X
connect to + and – with luster terminal (Reverse battery protection, but no function).
Put the plug (B) into socket (C) at the closer and screw down.
X
In the case of concealed connection (D)
Lay customer supplied connection cable for free-swing door closer 24 V (J-Y (ST) Y2x0,8) to supply terminal (D) of
X
the closer (Reverse battery protection, but no function).
IMPORTANT
Following the guideline for hold-open systems by the DIBt (German Institution for Construction Technology) the
installation of a circuit breaker is compulsory, if door closers with free-swing function are used.
6.5
Connecting wire cable to trigger
Suspend ball on wire cable in trigger lever (
X
Guide wire cable into funnel (
X
Pull out wire cable at deflection pulley (
X
Loosen clamping screw (
X
Push wire cable through clamping piece (
X
Tension wire cable (
X
Push trigger slide up to stop (
X
Tighten clamping screw (
X
Shorten wire cable to an excess of 30-50 mm to outer edge of guide rail (
X
GF
1.
GB 5
1.).
2.).
3.).
4.).
5.).
6.).
7.).
8.).
6.
9.).
2.
7.
9.
4.
8.
TS 5000 ISM EFS
Fig.: 6.4.1
5.
3.
SF
Fig.: 6.5.1