SPARKY PMW 1212CE Notice Originale page 10

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 33
WARNING: Using this power tool with
accessories differing from the described here-
with may cause accidents during operation.
The possibility to connect an operating tool
does not mean the machine is designed to be
used with it.
Using this power tool with accessories differ-
ing from the described herewith and all risks
for your health resulting from such use are en-
tirely on YOUR OWN RESPONSIBILITY!
WARNING: Always connect this
power tool to a socket with protective neutral.
Connecting the power tool to a socket with-
out protective neutral will cause risks for your
health and it is on your responsibility.
WARNING: Never use the power
tool without the PRCD delivered with the ma-
chine!
WARNING: Always test the PRCD
proper functioning before you start operation!
In case the PRCD does not function properly
do not start operating the power tool; but con-
tact the nearest authorised service centre!
WARNING: Prior to connecting the
power tool to the liquid feed system always
check the hoses and other critical parts which
may be damaged!
WARNING: When connecting to the
liquid feed system never use a source with
operating liquid pressure greater than the
maximum stated in the specifications of this
manual!
ANY USE Of THE POWER TOOL OTHER
THAN
THE
DESCRIBED
WELL AS ALL DERIVING RISKS fOR YOUR
HEALTH SHALL BE ENTIRELY ON YOUR
OWN RESPONSIBILITY!
PRIOR TO INITIAL OPERATION
▪ Make sure the power supply voltage corre-
sponds to the value indicated on the name
plate with technical data of the tool.
8
EN
▪ Check that the supply socket is connected to
▪ Check the pressure of the liquid feed system
▪ Check all connections of the liquid feed sys-
▪ Always check the position of ON/OFF switch.
▪ Make sure that the cord, PRCD and the plug
▪ In case the work area is remote from the pow-
▪ Check that the auxiliary handle is properly
CHECKING THE PRCD
Ensure that the ON/OFF switch (5) is in switched
off position.
Connect the cord plug to a socket with protec-
tive neutral.
Take the PRCD in your hand and press the ON-
I-RESET button. The PRCF LED indicator shall
start to glow. (Fig.1)
Switch the machine on by sliding the switch (5)
forward. The machine shall start to work.
Press the О-Test button. The PRCD shall switch
off, the LED indicator shall stop glowing and the
machine shall stop. (Fig.2)
HERWITH
AS
Slide the switch (5) backward to switch the ma-
chine off before you attempt to start the machine
again.
the protective neutral.
source. It shall be less or equal to the stated
in this manual.
tem. Loosening the coupling flanges, cracked
or torn hose, damaged or missing parts of the
water tap or connector are not allowed.
The power tool must be connected to the
power supply socket only when this switch is
in OFF position. If the plug is connected to
a receptacle while the power switch is in the
ON position, the power tool will start operating
immediately upon checking the PRCD, which
could cause a serious accident.
are in order. If the replacement of the supply
cord or PRCD is necessary, this has to be
done by the manufacturer or his agent in or-
der to avoid a safety hazard.
WARNING: Always switch off and un-
plug the power tool prior to any adjustment,
servicing or maintenance.
er source, use as short as practicable exten-
sion cord with proper cross-section.
mounted and reliably tightened.
PMW 1212CE ● CMW 1212CE

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cmw 1212ce

Table des Matières