Whale SH2201 Instructions D'installation Et D'utilisation page 2

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 42
Fig. 27
Installed Control Panel
Fig. 28
Connect 12V d.c. Connector
Fig. 29
Connect 12V d.c. to Interface Plate
Fig. 30
Completed Installation - Internal
Fig. 31
Completed Installation - External
Fig. 32
Control Panel
Fig. 33
Flue Type - for Vehicle in Motion
Fig. 34
Flue Type - for Standard Installation
1.
PRINCIPLES OF OPERATION
This Whale® Space Heater Mk II is a gas only blown air space heater. Nominal heat output is 2kW on gas. The
compact design provides versatility in installation locations and requires minimal maintenance. The vehicle's internal
temperature is set by a Control Panel which can be manually adjusted to a wide range of temperature settings or for
warm weather ventilation. Key enhancements to the Mk II design are improved insulation, improved service access
and a lighter, more compact design.
2.
SPECIFICATION
Read the following carefully before installation
Model: SH2201 (inside vehicle) Maximum dimensions: Height: 230mm, Width: 157mm, Length: 634mm
SH2211 (under-floor) Maximum dimensions: Height: 121mm, Width: 290mm, Length: 714mm
Countries of Destination: AT, BE, BG, CH, CY, CZ, DE, DK, EE, ES, FI, FR, GB, GR, HU, HR, IE, IS, IT, LT, LU, LV,
MT, NL, NO, PT, SE, SI, SK, TR
Weight: Inside Vehicle Installation 5.7kg
Underfloor Installation 5.8kg
Gas:
Butane 28-30mbar - CAT I 3+ (28-30/37), Butane/Propane 30mbar - CAT I 3B/P (30)
Propane 37mbar - CAT I 3p (37)
Gas Consumption (M) 150g/h
Classification of Heater: Type:
Nominal Heat Input: Gas 2.0kW
Battery Supply
Nominal voltage: 12V d.c.
Operating range: 10.0V d.c. min. to 15V d.c. max.
Maximum current d.c. gas operation: 1.7 Amps (0.01 Amps on standby)
Maximum current d.c. electric operation: 2.2 Amps (0.01 Amps on standby)
Dry Storage Temperature: -20°C to 70°C
Hot Air Duct Diameter: 60mm ID
Flue Diameter: 22mm ID
Maximum Exhaust Flue Length: 2m
Minimum Exhaust Flue Length: 0.75m
Maximum Combustion Air Flue Length: 2m
Minimum Combustion Air Flue Length: 0.75m
C 53 (Fanned) Normal Installation
C 13 Vehicle In Motion Installation
2