Important: At least one Hot Air Outlet Vent must be permanently open. The Hot Air Duct must not be fed into the
centre branch of a T fitting (see Fig. 22).
Ducting
Hot Air
Hot Air
Fig. 22a Incorrect Tee Fitting Orientation
Step 9 Internal and Underfloor Installation - Fitting Cold Air Supply
The Whale® Space Heater must be adequately supplied with cold air. If the Space Heater is installed in a bed box or
another confined space: vents into the area must be fitted or ducting used to supply the Space Heater with cold air.
If a vent is fitted, it must be no smaller than one designed for use with 60mm ducting. If ducting is fitted, it must
supply air from the living space of the vehicle. To fit the ducting, push it onto the cold air inlet at the Space Heater
where it will be gripped by the nozzle.
Cold Air Inlet
Cold Air Duct
Fig. 23 Internal Installation - Connect to Cold Air Duct
Step 10 Mounting of Whale® Control Panel
When mounting the Whale® Control Panel, find a suitable convenient and accessible position. For good temperature
control, select a position away from draughts and approximately 1.5m above the floor. Ensure suitable access for
Wiring Loom Connection and Cable. Note that the Cable supplied with the retail Space Heater to connect the Control
Panel to the Space Heater is 3.5m long.
The minimum depth behind panel for wiring must be 40mm. If using a Control Panel specific to the manufacturer of
the vehicle the electrical connections must be made in accordance with Step 11.
The Whale Control Panel requires a cut out 95mm wide x 42mm high. Feed the wires through the cut out in the wall
and locate into desired position. Secure with 4 screws (No.4 x
In some instances, it may be necessary to make the wiring connections in Step 11 before securing the Control Panel
to the wall.
Please note: It may be possible to retrofit the Whale® Control Panel into existing frames.
Tee Fitting
Ducting
Hot Air
Ducting
Hot Air Outlet
Hot Air Duct
Ducting
Hot Air
Hot Air Outlet
Fig. 22b Correct Tee Fitting Orientation
Hot Air Outlet
Fig. 24 Underfloor Installation
3
") provided, then clip on the surround frame.
4
13
Hot Air
Ducting
Tee Fitting
Ducting
Cold Air Duct
Vehicle Floor
Hot Air Duct
Hot Air Outlet
Cold Air Inlet