Whale SH2201 Instructions D'installation Et D'utilisation page 15

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 42
Retail Installation - Part Number: SH2202
The Space Heater and Control Panel come complete with electrical connectors fitted.
Step i
Connect the 12 way electrical connector with the unattached red and white leads to the 12 way connector on the
Space Heater.
Step ii
Route the wire to the Control Panel and connect the 6 way electrical connector to the 6 way connector on the Space
Heater.
Step iii
Route the 3 way electrical connector to the 3 way connector at the Control Panel.
Step iv
Secure the wire close to the Control Panel ensuring that there is no strain on the wires at the switches.
Step v
Connect the free red lead coming from the 12 way connector to a 12V d.c. supply.
Connect the free white lead to the caravan 0V d.c. supply.
Please note: Whale recommends that a 5 amp automotive fuse is fitted in the 12V d.c. supply.
12 Way Connector
Fig. 28 Internal Installation - Connect 12V d.c.
Warning: The appliance must not be supplied through an external switching device, such as a timer or a circuit that
is regularly switched. This is to avoid an inadvertent resetting of the thermal cut out.
Completed installation
Fig. 30 Completed Internal Installation
Please note: After completing the installation, a full function check including gas soundness must be carried out to
ensure the appliance has been installed and operates correctly. The gas soundness check must be carried out by an
accredited LPG gas engineer and a test certificate issued.
Space Heater
Cold Air Inlet
Cold Air Duct
Hot Air Outlet
Cold Air Inlet
Vehicle Floor
Fig. 29 Underfloor Installation - Connect 12V d.c.
Fig. 31 Completed Underfloor Installation
15
Hot Air Duct
Vehicle Floor
12 Way Connector
Hot Air Outlet

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sh2211b

Table des Matières