A Gas Pressure Test Point must be fitted to the inlet of the appliance.
When the gas line is complete, all joints must be tested for leaks using Leak Detection Solution.
N.B. Never with a naked flame.
The gas pressure must be verified at the pressure test point.
Please note: The operating pressure for the gas supply must be either 28-30m Bar Butane or 30m Bar-37mbar
Propane.
Cold Air Inlet
Space Heater
Hot Air Outlet
Gas In
Vehicle Floor
Gas Pipe
Fig. 18 Internal Installation - Connect to Gas Supply
Vehicle Floor
Gas Pipe
Gas In
Space Heater
Fig. 19 Underfloor Installation - Connect to Gas Supply
Step 8 Internal and Underfloor Installation - Fitting Hot Air Ducts
To fit the ducting, push it onto the 'hot air outlet', where it will be gripped by the nozzle.
Cold Air Inlet
Hot Air Outlet
Vehicle Floor
Ducting
Fig. 20 Internal Installation - Connect to Hot Air Duct
If fitting the Space Heater underfloor, fit the air duct into the hot air outlet on the Space Heater.
Vehicle Floor
Duct
Cold Air Inlet
Hot Air Outlet
Fig. 21 Underfloor Installation - Connect to Hot Air Duct
12