9.1.1
Daily
Visual inspection of the pneumatic Crimp Machine UP 14 Z.
+
Check air pressure (max. 6 bar.) of the house installation (manometer not in the scope of
+
the delivery).
Check oil-level of service unit of the house installation (not in the scope of the delivery).
+
9.1.2
Monthly
Lubricating all moving levers and bolts.
+
Procedure:
1. Disconnect pneumatic supply.
2. Remove left and right housing cover.
3. Lubricate all moving levers and bolts with Blasolube Fluid Art.-No. 00761-01.
4. Mount left and right housing cover.
10
Problem Handling and Fault Diagnostics
DANGER
Due to the risk of hand or finger injury, never try to reach into the machine before having
+
assured that the machine is disconnected from the air supply. Disconnect the air supply
before changing the safety guard and the dies.
CAUTION
Before starting maintenance, disassembly or repair work, the crimping machine must be
+
disconnected from air supply.
Maintenance work may be performed only by authorized and properly trained staff. The
+
housing and the covers in particular may only be removed by specially trained staff.
When working with the pneumatic Crimp Machine UP 14 Z, do not wear loose clothing,
+
jewellery or long, loose hair that can get caught in the pneumatic Crimp Machine UP 14 Z.
Work with caution.
+
Before commissioning the machine, it is always important to check whether all safety
+
devices, especially the safety guard and the die set, are installed and are functioning
correctly.
In the event of a problem our customer service personnel will be able to help you.
Service address:
WDT ToolTech AG
Eichenstraße 6
CH-8808 Pfäffikon (SZ)
Schweiz
Telephone: +41 (0) 55 417 00 30
Please have the following information ready when you contact service.
Machine Type
+
Machine Serial Number
+
BDA UP 14 Z – 03/15 – REV. 0
Page 42 / 71