D
Danger!
Before the pump is removed from the installation / machine or the shaft sealing is disassembled, ensure
that all product inlet and outlet bores of the pump are pressure‐free.
On slackening of the fastening screws hot gases or melt may emerge. Wear protective clothes, particu
larly a face guard! Observe the safety instructions provided in Chapter 1.9.
∙
When loosening the sealing chamber fastening screws or when opening the vent connection (opposite
to the product outlet in case of drum pumps), harmful sealing liquids may spurt out or harmful gasses
may escape. Wear appropriate protective clothing. Always loosen the top screw of the sealing cham
ber first for the accumulated gas to escape.
∙
Protect the pump against fast and uneven cooling down. Do not place on metal surfaces, avoid draft.
3.5
Storage of Installation Parts / Spare Parts
If the pump is to be temporarily stored prior to mounting into the installation / machine, then it must be
kept in the original packing.
The storage of the pump or separate parts must satisfy the following conditions:
∙
Ambient temperature:
∙
Rel. air humidity:
∙
For already installed pumps / pump sets which have not yet been taken into operation, the same con
ditions apply.
∙
If the pump is stored, the inlet must be filled with a low‐viscosity silicon oil. Filling is to occur while the
drive shaft is slowly rotated in the prescribed direction of rotation, until the medium can be seen to flow
out of the outlet openings. Next, seal the inlet and outlet holes, using the appropriate protective plugs /
caps.
∙
The pump body must in all cases be greased using a resin‐free preservation oil or similar product.
Kunde:
Basis
15 to 25 C
max. 60%
Auftrag:
000000-000
Ausgabe:
02.12
Seite
9