been read-in, otherwise the new tariffs are
activated and the previous ones deleted.
Procedure for manual programming
(not possible if new tariffs have pre-
viously been programmed using a tariff
loading box):
• Press the «CHANGE TARIFF» key:
→ The «Tariff table» menu field appears
displaying:
– Row 1 / column 1
– Tariff value for row 1 / column 1
– Weight level for row 1 / column 1
– Arrow keys for selecting rows and
column numbers
– Keypad for value entries
• Use the « » arrow key to select the desi-
red table row (e.g. row 3).
→ Tariff value and weight level for row 3
column 1 appear.
• Use the « » key to select the desired co-
lumn (e.g. column 2).
→ Tariff value and weight level for row 3
/ column 2 appear.
• Enter the newly valid tariff value for row
3 / column 2 using the keypad.
60
→ Inverse display of the tariff value ente-
red appears.
• Confirm the tariff value by pressing the
«OK» key.
→ The entered tariff value is program-
med.
• Select the next line and column number.
etc.
Important:
– You can cancel an incorrect value (before
confirming it with the «OK» key) by pres-
sing the «CE» key (inverse display 0.00).
You can then re-enter the value correctly.
If, instead, you press the «CE» key a se-
cond time, the currently valid value (not
inverse) remains.
– Use the « » arrow to decrement the co-
lumn counter one column at a time.
– Use the « » arrow to decrement the line
counter one line at a time. This automati-
cally resets the column counter to «1».
– If you press the «CE» key after confir-
ming a value using the «OK» key, not on-
ly the line, but also the column counter,
is reset to «1».
– If you press the «CE» key in position «1»
for the line and column counters, the sy-
stem returns to the Info/Setup menu.
– After you press the key field with the dis-
play for the set tariff value and the pro-
grammed weight level, the system swit-
ches to weight-level changes («Weight»
displayed inverse). This allows implemen-
ting changes in the weight levels (same
procedure as for tariff changes). Pressing
again on the display field initiates a
switch to tariff value programming («Ta-
riff» displayed inverse).
• Once you have finished making tariff
changes, press the «OK» key again.
→ «Update tariffs?» appears in the dis-
play.
• Press the «YES» key to accept your tariff
changes.
or:
Press the «NO» key to reject your tariff
changes.
5.9.22
Storing a macro program *
The franking value, automatic setting of
the additional postal sender cliché (country-
specific/depending on system configura -
tion) and other required details (postal ty-
pe/delivery destination/additional services)
for three frequently used mailings may be
stored in a macro program for subsequent
key-press recall (see section 5.2.5):
• In the «Automatic tariff calculation« wor-
king menu (see section 5.2.4), set the de-
sired combination of mailing parameters
(menu-guided or free).
→ Combination of mailing, calculated
postal charge, additional postal sender
cliché (if any).
• Select page 3 of the Info/Setup menu.
• Press the «SAVE MACRO» key.
→ Menu field for choosing the macro
number.
• Select the macro number for storing the
mailing combination, and confirm the
displayed number by pressing the «OK»
key.
→ Returns to the Info/Setup menu.
→ Macro programming is complete.
• Use the «Macro program» menu to verify
that the macro was correctly stored.
5.9.23
Saving the start menu
The sequence of the three working menus