MEASURE THE INSTALLATION
ROOF CAP
SOFFIT
CABINET
HOOD
HOOD
24" - 30" ABOVE
COOKING SURFACE
6
The minimum hood distance above cooking surface MUST
NOT BE LESS than 24" (to top of hood).
A maximum of 30" (to top of hood) above cooking surface is
highly recommended for best capture of cooking impurities.
Distances over 30" are at the installer's and user's
discretion; providing that the cabinet height permits.
CONTENTS
INCLUDED WITH THE HOOD:
GREASE
FILTERS
(2 - FOR 30" & 36" HOODS)
3 - FOR 42" HOODS)
(4)
HALOGEN
BULBS
(1) PARTS BAG CONTAINING:
(3)
WIRE
NUTS
SUCTION
CUP TOOL
(9)
#8 X 1/4"
DUCT
CONNECTOR
SCREWS
#10 X 5/8"
RD. HD.
MOUNTING
SCREWS
3¼" X 10" or
7" ROUND DUCT
(For vertical
discharge)
HOUSE WIRING
(Top or Back of hood)
WALL CAP
3¼" X 10" DUCT
(For horizontal discharge)
(1) 3¼" X 10"
DAMPER / DUCT
CONNECTOR
(1) 7" ROUND
DUCT
CONNECTOR
(1)
BULB
NON-DUCT
DIVERTER
(2)
#8 X 5/16"
MACHINE
SCREWS
&
(5)
(2)
#8 WASHERS
FOR NON-DUCT
DIVERTER
PREPARE THE HOOD
7
Remove parts bag from inside the hardware box included
with the hood.
8
Remove all protective polyfilm from the hood (stainless
steel hoods only).
9
Remove the Aluminum Filters from the hood.
10
Remove 6 Screws holding Bottom Pan to hood. Set bot-
tom pan and screws aside.
(1)
DUCT CONNECTOR
Remove 2 Screws holding Damper / Duct Connector
11
to hood. Remove damper/duct connector from inside the
hood.
FOR DUCTED INSTALLATIONS - Skip to Step 16.
(1)
PULL
(2)
DOWN
LIFT
OUT
DAMPER /
QP3 SERIES
Page 6
ALUMINUM
FILTERS