TO SET CLOCK:
Push (B) once – Hours will flash
Push (A) to decrease hours, Push (C) to increase hours.
Push (B) 2nd time – Minutes will flash
Push (A) to decrease minutes, Push (C) to increase minutes.
TO TURN DISPLAY ON & OFF:
(default from factory - display ON)
Push (B) 3 times: -d- will be seen
Push (C) once: (don) seen = display on (normal setting)
Push (C) 2nd time: (doff) seen = display off (no clock will be
seen)
TO TURN SLEEP MODE ON & OFF:
(default from factory - OFF)
Push (B) 4 times: -S- will be seen
Push (C) once: (SOFF) seen = All hood functions work
Push (C) 2nd time: (SON) seen = only fan and light buttons
work – display, ambient lights, delay off or timer will not
function.
TO TURN AMBIENT LIGHT SENSOR ON & OFF:
(default from factory - OFF)
Push (B) 5 times: -A- will be seen
Push (C) once: (AON1) seen = night-lights on when room very
dark.
Push (C) 2nd time: (AON2) seen = night-lights on when room is
less dark.
Push (C) 3rd time: (AOFF) seen = night-lights no longer come
on automatically.
Note that the feature menu can be exited any time by not press-
ing any button(s) for 10 seconds or by scrolling through the entire
feature menu.
B
C
HEAT SENTRY SYSTEM
This range hood is equipped with an advanced Heat Sentry
system that monitors excessive temperature and automatically
adjusts the fan to the appropriate setting.
1) If the fan is on, the Heat Sentry system will increase the fan
setting when the temperature is elevated. If the temperature con-
tinues to rise, the Heat Sentry system will continue to increase
the fan setting until the temperature is stabilized or reduced. The
flashing light above the fan button shows the Heat Sentry system
fan setting. Once the temperature has reduced, the Heat Sentry
system will change the fan to the original setting.
2) If the fan is off, (CANADIAN VERSION DOES NOT HAVE
THIS FUNCTION) the Heat Sentry system will automatically turn
the fan on to its highest speed when the temperature is above
normal. When the Heat Sentry system is on, the light above the
high speed fan button will flash on and off. After the temperature
has lowered to normal, the fan speed will be reduced until the
temperature has stabilized, then the fan will turn off.
FUSES
MAIN
FUSE
The Range Hood Control Board contains a Main Fuse and a
Light Fuse to protect the controls from power surges. If a fuse has
opened (blown), the green fan setting or light setting indicators will
not operate properly when the fan or light buttons are pressed, and
the fan and lights will not turn on.
New fuses can be purchased at your local electronic supply store.
Use 8A, 120V, 5 mm diameter, 20 mm long, fast-acting, cartridge-
type fuses.
To replace a fuse (by qualified person(s):
1. Disconnect power at service entrance.
2. Remove filters and bottom pan.
3. Remove and inspect fuse. If it is not open (blown), additional
diagnostics are needed.
QP3 SERIES
Page 3
RANGE HOOD CONTROL BOARD
LIGHT
FUSE