TFA No. 98.1035 Anleitung 06.11.2006 14:53 Uhr Seite 6
ANALOG
– Radio controlled projection clock with weather station

1. Functions

• Projection of the time and outdoor temperature onto a wall
or ceiling (digital)
• Highest precision radio-controlled clock
• Analogue display with pointer
• Alarm with snooze function
• Indication of weekday
• Outdoor temperature and humidity wireless (433 MHz) via up
to 3 transmitters, range approx. 60 m (free field), with ten-
dency indicator and adjustable temperature alarm
• Indoor temperature and humidity with comfort level indicator
• Maximum and minimum values
• Weather forecast with symbols and tendency of atmospheric
pressure
• Backlight
• Incl. Batteries 4 x 1,5 V AA and power adapter 230V
• Measuring range:
Indoor temperature:
Outdoor temperature:
Humidity:
2. Elements (Figures p. 2)
2.1 Receiver (Display unit)
LCD
A: Analogue clock
B: Weather Forecast with barometer pressure trend
C: Weekday
D: Indoor and outdoor temperature and humidity with trend in-
dicator
Buttons
E: ALARM button - Alarm time setting
F: ALARM ON/OFF button
G: CONTINUE PROJECTION button - ON/OFF
H: TEMP ALARM button – Display of temperature alarm or setting
of upper and lower limit
I: MEM button – Recall of maximum and minimum values
J: SET button - °C/°F and weekday language setting
K:
button – Decrement of digits
L:
button – Increment of digits and channel searching
M: CHANNEL button - Change IN – channel 1 – 2 - 3
10
-5...+50°C (23...+122°F)
-20...+50°C (-4...+122°F)
25...90% rF
ANALOG
– Radio controlled projection clock with weather station
N: SNOOZE / LIGHT button
2.2. Thermo Sensor Unit (Transmitter)
A: LED indicator – Flashes once when the remote unit transmits a
reading
Flashes twice when the battery of the remote unit is low
B: Battery Compartment - 2 x 1.5V AA batteries
C: RESET button
D: CHANNEL Selecting Switch
E: Wall Mount Hole
F: °C/°F button

3. Getting started

• Open the battery compartment of the display unit and the
transmitter (screwed) and place both instruments on a desk
with a distance of approximately 1.5 meter. Check that no
other electronic devices are close. Insert the batteries first into
the battery compartment of the transmitter and immediately
afterwards in the display unit, observing the correct polarity.
• After the initial setup, the display shows 4, 8 or 12 o'clock and is
trying to receive the radio signal. When the time code is received
(max. 4 minutes), the radio-controlled time will be displayed. If
the time reception was not successful, remove battery and rein-
sert after 1 min. for retry. If necessary choose another position.
• The display unit automatically starts scanning the RF 433MHz
signal to register the Thermo Hygro Sensor Unit after batte-
ries are inserted. If the reception of outdoor temperature
fails, "- -" appears on the display. Check the batteries and try
it again. Check if there is any source of interference. Manual
initialization by pressing the
helpful.
• The wave display shows the signal receiving status of the main
unit:
Searching mode
Readings are registered
No signals
button for 2 seconds can be