If the riving knife has vertical misalignment, adjust as
follows using Fig. 38 and Fig. 40:
1.
Loosen the 2 hex socket head screws (AA)
2.
Make adjustments to (BB2) and (BB3), to align riving
knife to the blade. No adjustment is needed for
(BB1).
3.
Tighten screws (AA).
If the riving knife has horizontal misalignment, adjust as
follows using Fig. 38 and Fig. 41:
1.
Loosen the 2 hex socket head screws (AA).
2.
Adjust screw (BB2) to align the riving knife to the
blade, if still out of alignment then adjust (BB3) until
proper alignment is achieved. Do not adjust (BB1).
3.
Tighten screws (AA).
To reduce the risk of injury, turn unit off and disconnect it from power source before cleaning or
servicing, before installing and removing accessories, before adjusting and when making repairs. An
accidental start-up can cause injury.

KEEP MACHINE CLEAN

Periodically blow out all air passages with dry compressed air. All plastic parts should be cleaned with a soft damp
cloth. NEVER use solvents to clean plastic parts. They could possibly dissolve or otherwise damage the material.
Wear certified safety equipment for eye, hearing and respiratory protection while using compressed
air.

MAINTENANCE REMINDERS

Wear certified safety equipment for eye, hearing and respiratory protection while using compressed air. Specific areas
which require regular maintenance include:
RIVING KNIFE CLAMP PLATE: Keep this area free of dust and debris buildup. Blow out area regularly with
compressed air.
NOTE: If the riving knife clamp can't move freely, have the saw serviced by authorized service center personnel.
WORM GEARS: Keep the bevel gears free of dust and debris buildup. Blow out area regularly with compressed air.
Use a lithium-based multipurpose grease as needed on these gears.
CLEAN SAWDUST BUILDUP OUT OF CABINET PERIODICALLY: NOTE: Debris can also be removed from the saw
from below the throat plate, inside the dust port.
For assistance with your machine, visit our website at www.deltamachineryparts.com for a list of service centers or
call Delta Power Equipment at
FAILURE TO START
If your machine fails to start, check to make sure the prongs on the cord plug are making good contact in the
receptacle. Also, check for blown fuses or open circuit breakers in your power supply line. If the saw still does not
start, call Company's Customer Care Center at 1-800-223-7278.
RIVING KNIFE ALIGNMENT

MAINTENANCE

TROUBLESHOOTING

1-800-223-7278.
CORRECT
POSITION
MISALIGNMENT OF
RIVING KNIFE
DIRECTION OF
MISALIGNMENT
26
DEFLECTIVE
RIVING KNIFE
FIGURE 40
BLADE
FIGURE 41

Publicité

Table des Matières

Dépannage

loading

Table des Matières