MAINTENANCE
Preventive and regular maintenance will ensure a long trouble
free life to your heater.
WARNING
Never service heater while it is plugged in, operating or
hot. Severe burns or electrical shock can occur.
Every 50 hours of operation: disassemble filter and wash
with clean oil, remove upper body parts and clean inside and
ventilator with compressed air, check correct attachment
of H.T. connectors to the electrodes and check H.T. cables,
remove burner assembly, clean and check electrode settings,
adjust according to scheme "GAP OF ELECTRODES".
Flue Connections Diagram
Indirect Fired Construction Heater
VENTILATION
Description
A) Minimal 39"
B) Minimal 39"
C) The shortest
D) The same or bigger than the smokes outlet diameter of heater
E) Minimal 1m
1) Anti-wind device provided with the heater
2) Horizontal crossing with minimal upside angle pitch of 5
degrees°
3) Chimney 8" x 8" of minimal inside measure
4) Chimney anti-explosion flap door
5) External seating wall
6) Chimney ending H shape
N.B. Above recommendation indicative only. Have your
installation checked by local authority.
7
Operating Instructions and Owner's Manual