Specifications - HeatStar 4000IDG-HD Instructions D'utilisation Et Manuel Du Propriétaire

Publicité

Les langues disponibles

Les langues disponibles

IMPORTANT
Before using the heater, read and understand all instructions and
follow them carefully. The manufacturer is not responsible for
damages to goods or persons due to improper use of units.
GENERAL RECOMMENDATIONS
This indirect-fired heater runs on natural gas or L.P.G. and is fitted
with a flue to take the fumes away through the chimney.
Prior to shipping, the heater is configured for either natural gas
or LP, labeled on the gas selector valve for the correct fuel type
and given a complete functional test. To change the type of gas,
follow the detailed instructions indicated in section "CHANGING
TYPE OF GAS".
Always follow local ordinances and codes when using this
heater:
•Read and follow this owner's manual before using the heater.
•Use only in places free of flammable vapors or dust content.
• N ever use heater in immediate proximity of flammable
materials (the minimum distance must be 6 ft.).
•Make sure fire fighting equipment is readily available.
• M ake sure sufficient fresh outside air is provided according to
the heater requirements. Direct combustion heaters should
only be used in well vented areas in order to avoid carbon
monoxide poisoning.
• T he heater is installed near a chimney to take away the fumes
(see "Ventilation" on page 5) and connected to an electrical
switchboard.
• W hen the heater is connected to a flue pipe, the flue pipe
shall terminate in a vertical section at least 3 feet long and
sufficient draft shall be created to assure safe and proper
operation of the heater.
• N ever block air inlet (rear) or air outlet (front).
• I n case of very low temperatures add kerosene to the heating
oil.
• M ake sure heater is always under surveillance and keep
children and animals away from it;
• B efore starting the heater always check free rotation of
ventilator fan.
• I ndirect fired units only can be connected to air ducts to
distribute warm air, with respect to the max. static pressure
declared (see "TECHNICAL SPECIFICATION" sheet).
•Unplug heater when not in use.
Indirect Fired Construction Heater
TECHNICAL SPECIFICATIONS
Heat input
Air flow
Heat output
Supply pressure
Burner pressure
Fuel consumption
Natural Gas
Position of gas
selector value
Supply pressure
Burner pressure
Fuel consumption
LPG
Position of gas
selector value
Phase
Power
Voltage
supply
Frequency
Electric consumption
Adjustment of combustion air flap
Ring Nozzle
Gas inlet connection thread
Flue
Static pressure
Compulsory flue draft
Maximum air temperature
Dimensions, L x W x H
Base unit
Weight
Dimensions, L x W x H
Packaging
Weight
3
Operating Instructions and Owner's Manual
TABLE 1
HS 4000IDG
[kBTU/h]
380
[cfm]
3,250
[kBTU/h]
328.7
min 7' w.c.
[in WC]
max 10" w.c.
[in WC]
6.40
[CFH]
355.97
min 8' w.c.
[in WC]
max 13' w.c.
[in WC]
7
[CFH]
133.89
1
[V]
120
[Hz]
60
[W]
1400
[A]
13.0
[N]
3.0
N. 12 holes x
[in]
0.106"
[psi]
3/4" HPT
[in]
5.91
[in]
0.60
[in]
0.05
[°F]
250
72.3 x 31.6 x
[in]
30.4
[lb]
306
74.1 x 26.0 x
[in]
35.83
[lb]
361