Homa FW-TP 4/1 Manuel D'instructions Original page 28

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.3.1. Type plate
1Ph
3Ph
No.
1 Ph
1
Typ description
2
Serial number
3
Impeller diameter
Temperature of medium
4
5
Immersion depth
6
Weight
7
Hmax (delivery head max)
8
Hmin (delivery head min)
9
Qmax (delivery volume max) Qmax (delivery volume max)
10
Standard
11
Construction product test lab
12a
Year type test
12b
Declaration of performance
13
Build year
14
Motor type
15
IE Marking
16
Frequency
17
Voltage
18
Nominal current
19
Motor RPM
20
Power P1
21
Cos phi
22
Insulation class
23
Power P2
24
Start condenser
25
Operating condenser
26
Protection class
27
Operating class
Text field sales
28
28 | EngliSH
3 Ph
Typ description
Serial number
Impeller diameter
Temperature of medium
Immersion depth
Weight
Hmax (delivery head max)
Hmin (delivery head min)
Standard
Construction product test lab
Year type test
Declaration of performance
Build year
Motor type
IE Marking
Frequency
Voltage - 3Phase
Nominal current - 3Phase
Motor RPM
Voltage - Star Connection
Nominal current Star connection
Insulation class
Power P1
Cos phi
Protection class
Power P2
Operating class
Text field sales
3.3.2. Motor
The three-phase asynchronous motor consists of an en-
gine block and the engine shaft with the impeller assem-
bly. The circuit for the power supply is designed for the
maximal mechanical performance according to the char-
acteristics or the nameplate of the pump. The cable in-
lets as well as the circuit are sealed resistant to jet water
with respect to the pumped medium. The shaft bearing
is carried out by means of robust, maintenance-free and
permanently lubricated antifriction bearings.
General motor nameplate data
Operating mode with immersed motor
Permitted medium temperature
Insulation class
Protection class
Cable length
Voltage TP 4/1
Voltage TP 8/1
3.3.3. Monitoring equipment
Temperature sensor
The pump type FW/TP4/1 is provided with a temperature
sensor set in the motor winding, which switches the mo-
tor off in the event of overheating of the winding. After
cooling, the motor will restart automatically. The pump
type FW-TP8/1 is provided with a switchgear with a mo-
tor protection switch. This switches off the pump in the
event of overload.
Rotational direction check
No check is required for single-phase motors, since these
always run in the correct direction of rotation. Three phase
motors have the correct direction of rotation if connected
to a clockwise rotating field (U, V, W -> L1, L2, L3). HOMA
switchgears check the circuit for a clockwise rotating
field. If there is no clockwise rotating field, the red LED
flashes. Two phases have to be interchanged at the input
of the switchgear. For smaller pumps, the check can be
carried out by observation of the start-jerk. For this, place
the pump vertically onto the floor, slightly onto the edge
and switch on for a short time. When seen from above,
the pump rebounds slightly anticlockwise in correct direc-
tion of rotation. The direction of rotation is correct if the
pump moves anticlockwise, since the motor starts clock-
wise when seen from above.
ATTENTION
The direction of rotation
is correct if the
impeller/propeller rotates
in a clockwise manner
when viewing down from
top of the placed unit
Warning - rotating impeller! Do not touch the rotating
impeller or do not reach into the pump chamber
through the pressure socket! Never put your hands
into the pump chamber or touch the rotating parts in
operating mode. Switch the machine off and let the
rotating parts come to gridlock before carrying out
maintenance work or repair work!
S1
40°C
H
IP68
20 m
230V / 1Ph / 50Hz
400V / 3Ph / 50Hz
ATTENTION
The start reaction is
anti clockwise