The illustration shows the position of the devices.
A)Safety thermostat with automatic reset: cuts
off the mains electricity supply in case of plate
overheating.
Important
Tripping of the thermostat with automatic
reset is indicated by an "ALL" alarm on the
circuit board display.
B) Heat sensor: a heat sensor which cuts off opera-
tion of the appliance's central heating element if
components overheat. Once the cause of the prob-
lem has stopped and the plate temperature has de-
creased, operation is automatically restored.
Important
There are no indicator devices to signal
that the heat sensor has been tripped.
C) Heat sensor: a heat sensor installed on the
controlling circuit board which cuts off the
mains power supply if the board overheats.
Once the cause of the problem has stopped
and the temperature has decreased, opera-
tion is automatically restored.
SAFETY AND INFORMATION SIGNS
The illustration shows the position of the signs pro-
vided.
IT
A)Nameplate with manufacturer and appliance
data.
GB
B)General hazard: read the manual carefully be-
fore carrying out any procedure.
DE
C)General hazard: when washing the appliance do
not point pressurized water jets at it..
D)General hazard: dry operation is forbidden.
FR
E)General hazard: all relevant regulations must be
complied with. "Install in compliance with the rel-
ES
evant regulations and use in well ventilated
premises only".
F) General hazard: all relevant regulations must be
complied with. "No liability is accepted in case of
failure to comply with the installation and com-
missioning instructions".
G)CE marking: indicates that the appliance is com-
pliant with the relevant norms.
H)WEEE symbol: indicates that the appliance is
subject to specific waste disposal regulations.
L) Warning: Dangerous voltage
English
Important
There are no indicator devices to signal
that the heat sensor has been tripped.
- 4 -