2A3 – MODELS WITH FREE FALL
DRAINAGE
N.B.
The drainage line consists of a sump pit,
free flow, of proper size capable to dispose
twice the water flow indicated on the data
diagram. It must be close to the drain pipe
of the machine without bending, stretching,
jointing the pipe.
-
Drain line must reach sump pit with free
flow without constraints, stretching, bends,
kinks, or being forced.
-
Connect the waste outlet pipe to the main
drain pipe, fitting a trap, or place the outlet pipe
over an "S" trap set into the floor.
2B – ELECTRICAL CONNECTION
N.B.
All contacts must be mechanically open,
ground
line
included,
between contacts 3 mm, with magnetic
overload or fuses, calibrated for a max,
sustained current agree with machine plat.
It must be installed outside the machine but
close to it. It must feed one machine only at
time.
Machine cannot be connected to mains
using adapters, plug, cables or cable
extensions
not
properly
adequate
to
the
requirements.
-
Verify main specifications must comply with
indicated requirements on the data plate
located inside of the front bottom panel of the
machine (par. ID/RATING/DATA PLATE), that
exists for the connection, a main breaker with
proper size suitable for the machine and a
proper ground system.
WARNING!
THE
MANUFACTURER
RESPONSIBLE
FOR
INJURIES
CAUSED
GROUNDING. THE GROUND AND THE
ELECTRICAL CONNECTIONS SHOULD BE
IN
COMPLIANCE
REGULATIONS.
min.
distance
sized
and
machine
power
IS
NOT
DAMAGES
OR
FOR
IMPROPER
WITH
NATIONAL
The line cable can be replaced only with a
spare cable supplied by the manufacturer.
For replacement indicate machine type,
machine serial number and possible
modifications of the installation. Power
cable cannot be stretched kinked, pressed,
during
normal
operation,
anytime.
Earth equilibrating point on machine must
be connected to nearest appliance terminal
according to Safety Standards using a 2.5
– 10 mm.
service
or