2
- INSTALLER AND MAINTENANCE PERSON INSTRUCTIONS
ATTENTION
Specialists that install the machine are
foreseen to train the operators about
machine utilization and safety procedures
to be followed. They must provide a real
"demonstration" and verify that machine
instructions are available to the operators.
Following attentions should be taken:
The dishwasher shall be installed in
accordance with local
codes, or in the absence of local codes,
installed in accordance with the applicable
requirements in the National Electrical
Code, NFPA 70, Canadian Electrical Code
(CEC), Part 1, CSA C22.1, and Standard for
Ventilation Control and Fire Protection of
Commercial Cooking Operations, NFPA 96.
WARNING!
DO NOT OPEN THE DOOR QUICKLY IF
CYCLE IS NOT ENDED.
DO NOT DIP BARE HANDS IN WASHING
SOLUTION.
DO NOT TAKE OFF THE MACHINE PANELS
IF
THE
MACHINE
DISCONNECTED FROM THE POWER AND
WATER SUPPLY.
DO
NOT
BYPASS
PROTECTIONS
PANELS, OR OTHERS) PROVIDED BY THE
MACHINE MANUFACTURER IF NOT AT
THE
PRESENCE
SPECIALISTS THAT CAN TAKE PROPRER
CAUTIONS.
DO NOT UTILISE THE MACHINE TO WASH
GOODS OUTSIDE THE SCOPE FOR
WHICH IS PROVIDED FOR, OBJECTS OF
SHAPE, TYPE, SIZE, AND MATERIAL NOT
COMPATIBLE.
DO NOT OPERATE THE MACHINE IF NOT
PROPERLY CONNECTED, ACCORDING
TO THE SPECIFICATIONS AND
REQUIREMENTS OF THE LOCAL LAW
AND PRESCRIPTION OF
MANUFACTURER, MAKING SURE THAT
ALL SAFETY DEVICES ARE OPERATIVE.
ID/RATING/DATA PLATE
ID/Rating plate of the appliance contains
identification and technical data and is located
on the front panel.
HAS
NOT
BEEN
THE
MACHINE
(MICROSWITCHES,
OF
TRAINED
2A – WATER CONNECTION
N.B.
Shut-off valve, single direction, spool,
sphere, lid control type, which can shut
water supply off quickly and totally,
selected to assure water pressure and
flow as requested in the data diagram
supplied with each machine.
1- Position the dishwasher and level the
appliance by turning the relative height-
adjustable feet. (Fig.4)
Fig. 4
2- Connect the solenoid valve, which feed
the machine, to water shut valve, using
a flexible line. (Fig.5) Each machine
must have its own water line supply.
Fig. 5
2A1 – WATER SUPPLY PRESSURE
Check that dynamic water supply pressure,
measured between the appliance and the
main, as indicate at par. 1D - TECHNICAL
DATA / WATER PRESSURE. If the
pressure is too high, fit a suitable
pressure reducer on the inlet pipe. If the
pressure is low, install an additional
external pressure motor pump.
- In case of new or long term appliance
inactivity, drain the water line to eliminate
air bubbles and foreign bodies present in
new or unused water lines, which can
damage the machine.
2A2 – WATER HARDNESS
If
water
hardness
acceptable, install a water softener if in the
machine is not provided with an internal
one, of adequate size prior the feed
solenoid valve. (par.1D – Technical Data)
If there is a high concentration of mineral
residues in the water or high conductivity,
we
recommend
demineralization filter for 5/7° f.
is
higher
than
installing
the
6