3 ×50 g
Shock:
2 shocks each in 6 directions
acc. to EN 60 068-2-27
Electrical insulation:
All circuits (measuring inputs /
measuring outputs / power supply)
are electrically insulated
Regulations
Housing protection
(acc. to IEC 529
resp. EN 60 529):
IP 40
Terminals IP 20
Electrical standards:
Acc. to IEC 1010 resp. EN 61 010
Test voltage:
Power supply versus:
– all 3.7 kV, 50 Hz, 1 min.
Measuring inputs versus:
– measuring outputs 2.3 kV,
Measuring input 1 versus:
– measuring input 2
Measuring output 1 versus:
– measuring output 2
Environmental conditions
Commissioning
temperature:
– 10 to + 55 °C
Operating
temperature:
– 25 to + 55 °C
Storage temperature:
– 40 to + 70 °C
Annual mean
relative humidity:
≤ 75%
Altitude:
2000 m max.
Indoor use statement!
7. Exchanging frontplates
Apply gentle pressure to the transparent cover as shown in
Fig. 3 until pops out on the opposite side. The label in the
cover can be replaced and used for notes.
After replacing the label in the transparent cover, the transpa-
rent cover can be snapped into the front of the device again.
This is done by inserting it behind the edge at the bottom
and pressing it gently down and to the rear with the fi nger
until it snaps into place (right side of Fig. 3).
ON
(
Fig. 3. Left: Removing the transparent cover
Right: Inserting the transparent cover.
50 Hz, 1 min.
2.3 kV, 50 Hz, 1 min.
2.3 kV, 50 Hz, 1 min.
ON
(
8. Withdrawing and inserting the device
(9)
(2
Fig. 4
Insert the withdrawing handles (2) into the openings (9) until
they snap into place. Withdraw the front part together with
the main PCB out of the housing.
To reassemble the unit, insert the front part together with the
main PCB into the housing until the swallow-tailed sections
engage in each other.
9. Mounting
The SINEAX TV 808 can be mounted either on a top-hat rail
or directly onto a wall or mounting plate.
Make sure that the ambient temperature stays within
the permissible limits:
– 25 and + 55 °C!
9.1 Top-hat rail mounting
Simply clip the device onto the top-hat rail (EN 50 022) (see
Fig. 5).
Fig. 5. Mounting on top-hat rail 35 × 15 or 35 × 7.5 mm.
9.2 Wall mounting
While pressing the latch (4) in the base of the device (Fig. 6,
left) pull out the isolating amplifi er securing brackets (1). To
return the brackets to their original positions, the latch (5) in
the base of the device has to be depressed before applying
pressure to the securing brackets (1) (see Fig. 6, right).
(1)
(2)
(3)
(2)
(4)
(1)
ON
(
(
(1)
Fig. 6. Rear of device.
(1) Screw hole brackets
(2) Top-hat rail clip
(3) Rubber buffers
(4) Latch for pulling the
(5)
screw hole brackets
out
(5) Latch for pushing
(1)
the screw hole
brackets in
17