RS232

The subwoofer can be controlled via the RS232 port on the
amplifier panel. The subwoofer can be controlled by sending a
string of characters to the RS232 connector.

RS232WiringConfiguration

The RS232 communication socket uses a standard RJ45
connector. This should be wired as illustrated on the amp panel
and below.
1 2
3
4
5
6
7

RS232CommunicationSet-UpParameters

Baud Rate: 57600
Data Size: 8
Parity: None
Stop Bits: 1
Handshaking/ Flow Control: None

CommandProtocol

Each string of commands sent to the Subwoofer must follow the
same structural protocol. These commands are detailed in the
Command List opposite. To control the Subwoofer using RS232
commands, specific strings of characters (forming a command
string) must be sent via a RS232 terminal. Each command
string should be terminated by both:
<CR> (the ASCII carriage return character, 13 decimal)
<LF> (the ASCII line feed character, 10 decimal)
These are generally found in the RS232 terminal settings.
The Subwoofer replies to a valid command with the updated
information changed by a SET command, or the information that
was requested by a GET command. If the Subwoofer receives an
invalid command it will reply with ERROR<CR><LF>
Note: any SET command other than SET_O during Standby
is deemed invalid.
1.
Ground
2.
Ground
3.
Ground
4.
Ground
5.
Rx
6.
Tx
7.
Not used
8.
Not Used.
8
monitoraudio.com

CommandList

The following SET commands control the operation of the
Subwoofer
Command
Description
SET_O:1
Go to Power On
SET_O:0
Go to Standby
SET_M:1
Mute output
SET_M:0
Unmute output
Select the Preset
SET_S:X
Where X is in the range
1 - 4
Set the Volume Trim Level
SET_T:X
Where X is in the range
-12 - 12
SET_N:1
Turn Night Mode on
SET_N:0
Turn Night Mode off
Reply from Subwoofer
POWER_ON:1<CR><LF>
POWER_ON:0<CR><LF>
MUTE_ON:1<CR><LF>
MUTE_ON:0<CR><LF>
PRESET:X<CR><LF>
Where X is in the range
1 - 4
TRIM_LEVEL:X<CR><LF>
Where X is in the range
-12 - 12
NIGHT_MODE:1<CR><LF>
NIGHT_MODE:0<CR><LF>