7.5
SmOkiNg
A properly installed appliance should not smoke. If yours does, check the following:
•
Has the chimney had time to get hot?
•
Is the smoke passage blocked anywhere in the appliance, chimney connector or chimney?
•
Is the room too airtight and the air intake not connected to the outside? Try with a window partly open.
•
Is the smoke fl ow impeded by too long a horizontal pipe or too many bends?
•
Is it a weak draft perhaps caused by a leaky chimney, a cold outside chimney, too large a diameter of a
chimney, too short a chimney, or a chimney too close to trees or a higher roof?
7.6
BLOwEr OPErATiON
The TF100 comes with a circulation blower which is connected through a variable speed control mounted on
the rear panel of the furnace (lower right side corner). Once this control has been turned on (turn knob clock-
wise from its "OFF" position, note: fan speed is reduced as the knob is turned further in the clockwise direction)
cycling of the fan is controlled by a thermal switch located at the rear of the firebox. The fan will cycle on when
the firebox reaches 49°C (120°F) and off when the temperature drops below 39°C (102°F).