8.3
Removing salt crystals for pumps with plastic
lanterns (AK version)
Fig. 4
1.
Disconnect system from the power supply.
2.
Carefully remove the salt crystals from between the ridges on
the lantern (1) from above using a screwdriver.
3.
Remove falling salt crust from the motor base (2).
4.
Ensure that the motor shaft is completely free of salt crystals
and is visible.
5.
Turn the motor shaft on the fan side using a screwdriver. The
motor shaft must be easy to turn.
6.
Reconnect to the power supply.
8.4
Warranty
The warranty includes the devices delivered and all components.
However natural wear and tear (DIN 3151/DIN-EN 13306) on all
turning and dynamically loaded components, including electronic
components under tension, is not covered under the warranty.
Failure to comply with the safety instructions may void the
warranty.