Technical Data
8 Technical Data
8.1.1 General
• European Low Voltage Directives 73/23/EEC and 93/68/EEC
• European EMC Directives 89/336/EEC and 93/68/EEC
Safety Standards
IEC/EN 61010-1:1992/93 + A2:1995 Safety requirements for electrical equipment for
measurement, control and laboratory use.
Part 2-031 : 1994 Particular requirements for hand held probe assemblies for
electrical measurement and test.
600V CAT III Pollution degree 2
IEC/EN 61557 -1/-2/-4: 1997 /-10:2000
EMC Standards
Emission:
Class B according to IEC/EN61326:1997 +A1:1998; EN55011
Immunity:
EN 61000-4-2:1995 - B, EN 61000-4-3: 1996 - A
EN 61000-4-4:1995 - B, EN 61000-4-5: 1995 - B
EN 61000-4-6:1996 - A, EN 61000-4-8: 1993 - A
General:
Display:
1999 digit dual LC-display with special symbols, digit height 17
mm, 30 segment analogue bar with over- and underflow and
special display sign, EL backlight
Environmental condition
FOR INDOOR USE ONLY
Temperature ranges:
Working temp.:
-10° C ...+50° C
(+14° F ...+122° F )
Operating temp.:
0° C ...+35° C
(+32° F ...+95° F )
Storage temp.:
-20° C ...+60° C
( -4° F ...+140° F )
Reference temp.: +23° C
± 2° C
(+73° F
Temperature coefficient :
0.1 x operating error/K
Climatic class:
B2 (IEC 654-1), -5° C..+45°C,
5%...85% RH, no dew
± 4° F )