Instruction
Program function:
sequence in FB
A value input (target position) is requested by the TD 390 by a pulse
applied to input 32.5 (ON/OFF switch).
After entering a new value in the TD 390, the TD 390 displays the
entered value "New target xx.xxx m" (now in the "Display Messages"
operating mode) (see Section 3.2, DB51, 3rd text block)
FB13 (Name: TD390III)
:
:A
:S
:S
:
:A
:R
:A
:AN
:
:JC
:BEU
M001
:C
:L
:C
:T
:R
:S
:BE
TD 390
C79000–K8576–C292–01
Examples of Handling the TD 390
Request target position input
I
32.5
"Input requested"
F
60.0
Display 1st mess. for proc. vals.
F
18.7
FY 18 in DB5, DW10 (KY=018,057)
Input 32.6 (pulse): Cancel
I
32.6
Message display
F
0.5
"Input requested".
F
60.0
Reset by TD 390 if input
F
18.7
confirmed at TD.
=M001
DB57 with process values
DB
57
Read new target position
DW
8
DB51: text DB 1 (FY 0,1,2)
DB
51
Transfer new target position
DW
27
Cancel "Input requested"
F
60.0
Display. Text DB 1, 3rd message
F
0.5
Cont'd
3-9