TECHNICAL DATA
TYPE
Thermal power – output
Output
Fuel
Electrical supply
Motor
Ignition transformer
Pump
Absorbed electrical power
Minimum room temperature
Battery
Burner with CE marking in conformity with EC Directives:
EMC 2004/108/EC, Low Voltage 2006/95/EC, Machines 2006/42/EC.
The burner meets protection level of IP 40, EN 60529.
5
4
3
1 – Return line
2 – Suction line
3 – Gauge connection
4 – Pump pressure regulator
5 – Lock-out lamp and reset button
705M1
29 - 69 kW
2.45 - 5.8 kg/h
Light oil max. viscosity at 20 °C: 4 ÷ 6 mm
Kerosene max. viscosity at 20 °C: 1.6 ÷ 6 mm
24 V D.C ± 2 V
Run current 11.5 A – 2800 rpm
Secondary 8 kV – 16 mA
Light oil maximum pressure 15 bar (218 psi)
Kerosene maximum pressure 10 bar (145 psi)
Min. capacity 100 Ah
Fig. 1
6
7
7
D7817
6 – Air-damper
7 – Screws fixing air-damper
8 – Combustion head adjustment screw
9 – Vacuum gauge connection
1
GB
706M1
54 - 120 kW
4.5 - 10 kg/h
0.3 kW
0 °C
2
1
2
/s
2
/s
8
9
2903360