GB
Check that the unit is connected to the correct mains power supply voltage, and that it is protected by
the correct fuse size. A protective earth connection must be made, in accordance with regulations.
Recommended fuse sizes and minimum cable areas
TM
Origo
Mig 410
Voltage V
Current A
at100% duty cycle
at 60% duty cycle
at 50% duty cycle
Cable area mm
2 2 2 2
Fuse, slow A
TM
Origo
Mig 510
Voltage V
Current A
at100% duty cycle
at 60% duty cycle
Cable area mm
2 2 2 2
Fuse, slow A
NB: The mains cable areas and fuse sizes as shown above are in accordance with Swedish
regulations. They may not be applicable in other countries: make sure that the cable area and fuse
sizes comply with the relevant national regulations.
mi410,510e
Rating plate with supply connection data
3∼ 50 Hz
3∼ 50/60 Hz
230
400/415
28
16
42
24
45
28
4 x 6
4 x 2,5
25
20
3∼ 50 Hz
3∼ 50/60 Hz
230
400/415
43
25
68
39
4 x 16
4 x 6
63
35
- - 11 - -
3∼ 50 Hz
3∼ 60 Hz
500
230
13
28
19
41
20
45
4 x 2,5
4 x 6
20
25
3∼ 50 Hz
3∼ 60 Hz
500
230
20
43
31
68
4 x 6
4 x 16
35
63
3∼ 60 Hz
440/460
14
21
22
4 x 2,5
20
3∼ 60 Hz
440/460
23
35
4 x 6
25